A Crane Co. Company

Limited 24 Month Warranty

Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship 
under  normal  use  and  service  for  twenty-four  (24)  months  after  manufacture  date,  when  installed  and  maintained 
in  accordance  with  our  instructions.This  warranty  gives  you  speci c  legal  rights,  and  there  may  also  be  other  rights 
which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law 
(1)  the  duration  of  any  implied  warranties  associated  with  the  product  by  virtue  of  said  law  is  limited  to  the  same 
duration  as  stated  herein,  (2)  this  warranty  is  a  LIMITED  WARRANTY,  and  (3)  no  claims  of  any  nature  whatsoever 
shall  be  made  against  us,  until  the  ultimate  consumer,  his  successor,  or  assigns,  noti es  us  in  writing  of  the  defect, 
and  delivers  the  product  and/or  defective  part(s)  freight  prepaid  to  our  factory  or  nearest  authorized  service  station. 
Some  states  do  not  allow  limitations  on  how  long  an  implied  warranty  lasts,  so  the  above  limitation  may  not  apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY 
PRODUCT  SHALL  BE  TO  REPLACE  OR  REPAIR  AT  OUR  ELECTION,  F.O.B.  POINT  OF  MANUFACTURE  OR 
AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE 
NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

 Unless expressly 

stated otherwise, guarantees in the nature of performance speci cations furnished in addition to the foregoing material 
and  workmanship  warranties  on  a  product  manufactured  by  us,  if  any,  are  subject  to  laboratory  tests  corrected  for 
 eld performance. Any additional guarantees, in the nature of performance speci cations must be in writing and such 
writing must be signed by our authorized representative. Due to inaccuracies in  eld testing if a con! ict arises between 
the  results  of   eld  testing  conducted  by  or  for  user,  and  laboratory  tests  corrected  for   eld  performance,  the  latter 
shall  control. 

RECOMMENDATIONS  FOR  SPECIAL  APPLICATIONS  OR  THOSE  RESULTING  FROM  SYSTEMS 

ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND 
PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF 
SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This  warranty  shall  not  apply  when  damage  is  caused  by  (a)  improper  installation,  (b)  improper  voltage  (c)  lightning 
(d) excessive sand or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any 
modi cation of the original equipment will also void the warranty. We will not be responsible for loss, damage or labor 
cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without 
our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice 
and\or  our  speci c  recommendations.  The  purchaser  is  responsible  for  communication  of  all  necessary  information 
regarding the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR 

ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO TRAVEL EXPENSES, 
RENTED  EQUIPMENT,  OUTSIDE  CONTRACTOR  FEES,  UNAUTHORIZED  REPAIR  SHOP  EXPENSES,  LOST 
PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES 
ARE  CAUSED  BY  ANY  DEFECTS  IN  MATERIAL  AND\OR  WORKMANSHIP  AND\OR  DAMAGE  OR  DELAYS  IN 
SHIPMENT.  THIS  WARRANTY  IS  EXPRESSLY  IN  LIEU  OF  ANY  OTHER  EXPRESS  OR  IMPLIED  WARRANTY, 
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, 
without our prior written approval.

420 Third Street 

83 West Drive

Piqua, Ohio 45356 

Brampton, Ont. Canada L6T 2J6

(937) 778-8947 

(905) 457-6223

Fax (937) 773-7157 

Fax (905) 457-2650

www.cranepumps.com

Содержание SE51A

Страница 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario C...

Страница 2: ...18 22 SE HT SINGLE SEAL EXPLODED VIEW Fig 19 23 3SE DS DOUBLE SEAL CROSS SECTION Fig 20 24 3SE DS DOUBLE SEAL EXPLODED VIEW Fig 21 25 PARTS LIST 26 28 RETURNED GOODS POLICY 32 WARRANTY 31 WARRANTY RE...

Страница 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Страница 4: ...Filled Reservoir Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5 m 20 ft 6 1 m Cord Plug on 120 Volt 5HP 240 Volt 1 Phase Quick connect custom molded for sealing and s...

Страница 5: ...le Seal SE A SE HTA Single Seal SE AU SE HTAU Single Seal Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240...

Страница 6: ...6 Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models inches mm Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models 3SE L Single Seal 3SE DS Double Seal...

Страница 7: ...or basin that is free of hard debris like gravel stones sand or earth The sump lift station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage efflu...

Страница 8: ...rations Automatic Plug float cord into outlet then plug pump cord into float cord Manual Plug pump cord directly int outlet C 4 Electrical Connections C 4 1 Power and Control Cable The cord assembly m...

Страница 9: ...tamped on the pump identi cation plate to the available power D 2 Check Pump Rotation Before putting pump into service for the rst time the motor rotation must be checked Improper motor rotation can r...

Страница 10: ...5 3 14 4 SOW 0 570 14 5 40 80 52 00 3SE554L 0 5 600 3 60 1750 H B 1 0 3 4 14 4 SOW 0 570 14 5 77 60 89 76 3SE774L 0 75 200 240 1 60 1750 G K F 7 4 7 0 21 5 25 8 14 3 SOW 0 530 13 5 1 86 10 20 2 74 10...

Страница 11: ...he pressure does not hold then the leak must be located and repaired Pumps that have NOT had the oil drained from the Motor Housing The pressure test may be done with the oil at its normal level Remov...

Страница 12: ...volute 1 Position lockwasher 12 on cap screw 26 and screw into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service CAUTION Handle seal parts with extrem...

Страница 13: ...ing sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in...

Страница 14: ...ce station or Barnes Pumps Service department Inspect motor winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be...

Страница 15: ...eplacement parts ALWAYS furnish the following information 1 Pump serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item...

Страница 16: ...16 FIGURE 13...

Страница 17: ...17 FIGURE 13...

Страница 18: ...18 FIGURE 13 CONTIUED...

Страница 19: ...cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Страница 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...

Страница 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...

Страница 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...

Страница 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...

Страница 24: ...24 FIGURE 20 3SE DS Series Double Seal...

Страница 25: ...25 FIGURE 21 3SE DS Series Double Seal...

Страница 26: ...BS 070963 SE774L 3SE774L SE1074L 3SE1074L 029792BD 070963 3SE774DS 3SE1074DS 071354BS None SE794L SE744L 3SE794L 3SE744L SE1094L None SE1044L 3SE1094L 3SE1044L 071354BD None 3SE794DS 3SE744DS 3SE1094D...

Страница 27: ...a 084346TH 5 00 Dia 084346TJ 4 88 Dia 084346TK 4 75 Dia 084346TL 4 63 Dia 084346TM 4 50 Dia 084346TN 4 38 Dia 084346TP 4 25 Dia 084346TQ 4 13 Dia 084346TR 4 00 Dia 36 1 027344 t Gasket 39 1 014270 Pip...

Страница 28: ...ABLE LENGTH ITEM 16 120 VOLT 1 PHASE STD Temp ITEM 16 120 VOLT 1 PHASE High Temp ITEM 16 240 VOLT 1 PHASE 0 5HP STD HT ITEM 16 240 VOLT 1 PHASE 0 75 1HP STD HT ITEM 16 3 PHASE ITEM 55 OPTIONAL STD Tem...

Страница 29: ...29 Notes...

Страница 30: ...30 Notes...

Страница 31: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Страница 32: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Отзывы: