FIGURE 14

Reconnect motor and optional control leads to the underside 
of the terminal block(s) (21), (54 optional) as shown in Figure 
13. Note that the pins are numbered underneath the terminal 
block.  Place  o-ring  (20)  into  groove  in  terminal  block  and 
lubricate  with  dielectric  oil.  Press  the  terminal  block  (21) 
into  the  housing  so  it  seats  completely  below  the  snap  ring 
groove. Place snap ring (19) into groove in cable entry bore of 
housing. Repeat terminal block installation for control cable, if 
equipped.

F-4.4) Cable Assemblies:

Power/Control  Cable- 

Refi ll  the  cooling  oil  as  outlined  in 

paragraph  F-1.3.  Make  wire  connections  as  outlined  in 
paragraph F-4.3. Insert female end of cable plug into housing 
bore aligning timing mark with hole in terminal block (21) see 
Figure  15. 

  Compress  cable  plug  with  compression  fl ange 

(16a) by tightening hex bolts (11) into the housing (6). Torque 
to 132 in-lbs.

SECTION: G REPLACEMENT PARTS

G-1 ORDERING REPLACEMENT PARTS:

When ordering replacement parts, ALWAYS furnish the 
following information:
1. Pump serial number and date code. (Paragraph G-4)
2. Pump model number. (Paragraph G-3)
3. Pump part number. (Paragraph G-2)
4. Part description.
5. Item part number.
6. Quantity required.
7. Shipping instructions.
8. Billing Instructions.

G-2 PART NUMBER:

The part number consists of a six (6) digit number, which 
appears in the catalog. A one or two letter suffi x may follow 
this number to designate the design confi guration. This 
number is used for ordering and obtaining information.

G-3 MODEL NUMBER:

This designation consists of numbers and letters which 
represent the discharge size, series, horsepower, motor 
phase and voltage, speed and pump design. This number is 
used for ordering and obtaining information.

G-4 SERIAL NUMBER:

The serial number block will consist of a six digit number, 
which is specifi c to each pump and may be preceded by 
a alpha character, which indicates the plant location. This 
number will also be suffi xed with a four digit number, which 
indicates the date the unit was built (Date Code). 

EXAMPLE: A012345 0490.

Reference the six digit portion (Serial Number) of this number 
when referring to the product.

Содержание SE51A

Страница 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario C...

Страница 2: ...18 22 SE HT SINGLE SEAL EXPLODED VIEW Fig 19 23 3SE DS DOUBLE SEAL CROSS SECTION Fig 20 24 3SE DS DOUBLE SEAL EXPLODED VIEW Fig 21 25 PARTS LIST 26 28 RETURNED GOODS POLICY 32 WARRANTY 31 WARRANTY RE...

Страница 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Страница 4: ...Filled Reservoir Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5 m 20 ft 6 1 m Cord Plug on 120 Volt 5HP 240 Volt 1 Phase Quick connect custom molded for sealing and s...

Страница 5: ...le Seal SE A SE HTA Single Seal SE AU SE HTAU Single Seal Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240...

Страница 6: ...6 Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models inches mm Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models 3SE L Single Seal 3SE DS Double Seal...

Страница 7: ...or basin that is free of hard debris like gravel stones sand or earth The sump lift station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage efflu...

Страница 8: ...rations Automatic Plug float cord into outlet then plug pump cord into float cord Manual Plug pump cord directly int outlet C 4 Electrical Connections C 4 1 Power and Control Cable The cord assembly m...

Страница 9: ...tamped on the pump identi cation plate to the available power D 2 Check Pump Rotation Before putting pump into service for the rst time the motor rotation must be checked Improper motor rotation can r...

Страница 10: ...5 3 14 4 SOW 0 570 14 5 40 80 52 00 3SE554L 0 5 600 3 60 1750 H B 1 0 3 4 14 4 SOW 0 570 14 5 77 60 89 76 3SE774L 0 75 200 240 1 60 1750 G K F 7 4 7 0 21 5 25 8 14 3 SOW 0 530 13 5 1 86 10 20 2 74 10...

Страница 11: ...he pressure does not hold then the leak must be located and repaired Pumps that have NOT had the oil drained from the Motor Housing The pressure test may be done with the oil at its normal level Remov...

Страница 12: ...volute 1 Position lockwasher 12 on cap screw 26 and screw into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service CAUTION Handle seal parts with extrem...

Страница 13: ...ing sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in...

Страница 14: ...ce station or Barnes Pumps Service department Inspect motor winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be...

Страница 15: ...eplacement parts ALWAYS furnish the following information 1 Pump serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item...

Страница 16: ...16 FIGURE 13...

Страница 17: ...17 FIGURE 13...

Страница 18: ...18 FIGURE 13 CONTIUED...

Страница 19: ...cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Страница 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...

Страница 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...

Страница 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...

Страница 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...

Страница 24: ...24 FIGURE 20 3SE DS Series Double Seal...

Страница 25: ...25 FIGURE 21 3SE DS Series Double Seal...

Страница 26: ...BS 070963 SE774L 3SE774L SE1074L 3SE1074L 029792BD 070963 3SE774DS 3SE1074DS 071354BS None SE794L SE744L 3SE794L 3SE744L SE1094L None SE1044L 3SE1094L 3SE1044L 071354BD None 3SE794DS 3SE744DS 3SE1094D...

Страница 27: ...a 084346TH 5 00 Dia 084346TJ 4 88 Dia 084346TK 4 75 Dia 084346TL 4 63 Dia 084346TM 4 50 Dia 084346TN 4 38 Dia 084346TP 4 25 Dia 084346TQ 4 13 Dia 084346TR 4 00 Dia 36 1 027344 t Gasket 39 1 014270 Pip...

Страница 28: ...ABLE LENGTH ITEM 16 120 VOLT 1 PHASE STD Temp ITEM 16 120 VOLT 1 PHASE High Temp ITEM 16 240 VOLT 1 PHASE 0 5HP STD HT ITEM 16 240 VOLT 1 PHASE 0 75 1HP STD HT ITEM 16 3 PHASE ITEM 55 OPTIONAL STD Tem...

Страница 29: ...29 Notes...

Страница 30: ...30 Notes...

Страница 31: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Страница 32: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Отзывы: