15
FIGURE 14
Reconnect motor and optional control leads to the underside
of the terminal block(s) (21), (54 optional) as shown in Figure
13. Note that the pins are numbered underneath the terminal
block. Place o-ring (20) into groove in terminal block and
lubricate with dielectric oil. Press the terminal block (21)
into the housing so it seats completely below the snap ring
groove. Place snap ring (19) into groove in cable entry bore of
housing. Repeat terminal block installation for control cable, if
equipped.
F-4.4) Cable Assemblies:
Power/Control Cable-
Refi ll the cooling oil as outlined in
paragraph F-1.3. Make wire connections as outlined in
paragraph F-4.3. Insert female end of cable plug into housing
bore aligning timing mark with hole in terminal block (21) see
Figure 15.
Compress cable plug with compression fl ange
(16a) by tightening hex bolts (11) into the housing (6). Torque
to 132 in-lbs.
SECTION: G REPLACEMENT PARTS
G-1 ORDERING REPLACEMENT PARTS:
When ordering replacement parts, ALWAYS furnish the
following information:
1. Pump serial number and date code. (Paragraph G-4)
2. Pump model number. (Paragraph G-3)
3. Pump part number. (Paragraph G-2)
4. Part description.
5. Item part number.
6. Quantity required.
7. Shipping instructions.
8. Billing Instructions.
G-2 PART NUMBER:
The part number consists of a six (6) digit number, which
appears in the catalog. A one or two letter suffi x may follow
this number to designate the design confi guration. This
number is used for ordering and obtaining information.
G-3 MODEL NUMBER:
This designation consists of numbers and letters which
represent the discharge size, series, horsepower, motor
phase and voltage, speed and pump design. This number is
used for ordering and obtaining information.
G-4 SERIAL NUMBER:
The serial number block will consist of a six digit number,
which is specifi c to each pump and may be preceded by
a alpha character, which indicates the plant location. This
number will also be suffi xed with a four digit number, which
indicates the date the unit was built (Date Code).
EXAMPLE: A012345 0490.
Reference the six digit portion (Serial Number) of this number
when referring to the product.
Содержание SE51A
Страница 16: ...16 FIGURE 13...
Страница 17: ...17 FIGURE 13...
Страница 18: ...18 FIGURE 13 CONTIUED...
Страница 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...
Страница 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...
Страница 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...
Страница 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...
Страница 24: ...24 FIGURE 20 3SE DS Series Double Seal...
Страница 25: ...25 FIGURE 21 3SE DS Series Double Seal...
Страница 29: ...29 Notes...
Страница 30: ...30 Notes...