4
DISCHARGE .............
2” NPT, Female, Vertical, Bolt-on Flange
LIQUID TEMPERATURE:
Standard
............
104°F (40°C) Continuous
High Temp
.........
200°F (93°C) Continuous
VOLUTE ....................
Cast Iron ASTM A-48, Class 30
MOTOR HOUSING ...
Cast Iron ASTM A-48, Class 30
SEAL PLATE ...........
Cast Iron ASTM A-48, Class 30
IMPELLER:
Design ...............
2 Vane, open, with pump out vanes on
back side. Dynamically balanced, ISO G6.3
Material
.............
Cast Iron ASTM A-48, Class 30
SHAFT .......................
416 Stainless Steel
SQUARE RINGS .......
Buna-N
HARDWARE .............
300 Series Stainless Steel
PAINT ........................
Air Dry Enamel
SEAL:
Design
..............
Single Mechanical
Material
..............
Carbon/Ceramic/Buna-N
Hardware -300 Series Stainless
CORD ENTRY ...........
15 ft. (5 m), 20ft. (6.1 m) Cord with plug
on 120 volt & .5HP, 240 volt, 1 phase.
Quick connect custom molded for sealing
and strain relief
SPEED ......................
1750 RPM (Nominal)
UPPER BEARING .....
Single Row, Ball, Oil lubricated
Load
...................
Radial
LOWER BEARING ....
Single Row, Ball, Oil lubricated
Load
...................
Radial & Thrust
MOTOR:
Design
..............
NEMA L -Single Phase, NEMA B -Three
phase Torque Curve, Oil Filled, Squirrel
Cage Induction
Insulation
...........
Class B, Class F for High Temp.
Class F on selected models
SINGLE PHASE ........
Permanent Split Capacitor (PSC)
Includes Overload Protection in Motor
THREE PHASE .........
200-240/480 is Tri-Voltage notor 600V.
Requires overload Protection to be
included in control panel
LEVEL CONTROL ...."A" -
Wide Angle, PVC, Mechanical,
20 ft (6.1m) cord with Piggy-Back Plug, N/O
"AU"-
Wide Angle, Polypropylene,
Mechanical, N/O Integral to pump.
ON and OFF Points are adjustable
OPTIONAL EQUIPMENT
Seal Material, Impeller Trims,
Additional cord, Normally Closed Temperature Sensors with
cord for 3 phase pumps (Requires relay in control panel),
*Inlet Strainer for High Temperature Models.
(*) 3/4” Spherical solids handling with optional inlet stainer.
DISCHARGE ............
3” NPT, Female, Vertical, Bolt-on Flange
LIQUID TEMP ...........
104°F (40°C) Continuous
VOLUTE ....................
Cast Iron ASTM A-48, Class 30
MOTOR HOUSING ...
Cast Iron ASTM A-48, Class 30
SEAL PLATE ...........
Cast Iron ASTM A-48, Class 30
IMPELLER:
Design
...............
2 Vane, open, with pump out vanes on
back side. Dynamically balanced, ISO G6.3
Material
.............
Cast Iron ASTM A-48, Class 30
SHAFT
.....................
416 Stainless Steel
SQUARE RINGS .......
Buna-N
HARDWARE .............
300 Series Stainless Steel
PAINT ........................
Air Dry Enamel
SEAL:
Design
..............
Single Mechanical or Tandem Mechanical
with Oil Filled Reservoir
Material
..............
Carbon/Ceramic/Buna-N
Hardware -300 Series Stainless
CORD ENTRY .............
15 ft. (5 m), 20 ft. (6.1 m) Cord. Plug on
120 Volt & .5HP. 240 Volt 1 Phase Quick
connect custom molded for sealing
and strain relief
SPEED ......................
1750 RPM (Nominal)
UPPER BEARING .....
Single Row, Ball, Oil lubricated
Load
...................
Radial
LOWER BEARING ....
Single Row, Ball, Oil lubricated
Load
...................
Radial & Thrust
MOTOR:
Design
..............
NEMA L -Single Phase, NEMA B -Three
phase Torque Curve, Oil Filled, Squirrel
Cage Induction
Insulation
...........
Class B
Class F on selected models
SINGLE PHASE ........
Permanent Split Capacitor (PSC)
Includes Overload Protection in Motor
THREE PHASE ............
200-240/480 is Tri-Voltage. 600V. Requires
Overload Protection to be included in
control panel
OPTIONAL EQUIPMENT .....
Seal Material, Impeller Trims,
Additional cord, Normally Closed Temperature Sensors with
cord for 3 phase pumps (Requires relay in control panel),
Normally Open Moisture Sensor with cord for DS pumps.
SECTION: A - PUMP SPECIFICATIONS:
2” Pumps (Standard & High Temperature)
3” Pumps
IMPORTANT ! - Standard Temperature
1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT
DAMAGE TO MOTOR AND/OR SEALS.
2.) THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED
AS CLASS I DIVISION II HAZARDOUS LOCATIONS.
3.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS
SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER
FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70
AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER
PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH
PUMPED MEDIA IS A COMMON OCCURRENCE.
IMPORTANT ! - High Temperature
1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT
DAMAGE TO MOTOR AND/OR SEALS.
2.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS
SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
3.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER
FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA
70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS
NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL
WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH
PUMPED MEDIA IS A COMMON OCCURRENCE.
4.) MUST USE A
HIGH TEMPERATURE
WIDE ANGLE LEVEL CONTROL IN
HIGH TEMPERATURE APPLICATIONS.
Содержание SE51A
Страница 16: ...16 FIGURE 13...
Страница 17: ...17 FIGURE 13...
Страница 18: ...18 FIGURE 13 CONTIUED...
Страница 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...
Страница 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...
Страница 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...
Страница 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...
Страница 24: ...24 FIGURE 20 3SE DS Series Double Seal...
Страница 25: ...25 FIGURE 21 3SE DS Series Double Seal...
Страница 29: ...29 Notes...