background image

12

F-2) Impeller and Volute Service:
F-2.1) Disassembly and Inspection:

To clean out volute (1) or replace impeller (33), disconnect 
power, remove hex bolts (26), and lockwashers (12), 
vertically lift motor and seal plate assembly from volute 
(1) see Figure 5. Clean out body if necessary. Clean and 
examine impeller (33), for pitting or wear and replace if 
required, inspect gasket (36) and replace if cut or damaged. 
If the impeller (33) needs replacing, place a fl at screwdriver 
in the slot of the end of the shaft to hold the shaft stationary 
while unscrewing the jam nut (66) and impeller (33).

F-2.2) Reassembly:

To install impeller (33), clean the threads with thread 
locking compound cleaner. Apply removable Loctite® 603 
or equivalent to shaft threads. Screw impeller onto the shaft 
hand tight while using a screwdriver in the slot at the end of 
the shaft to hold it stationary. Apply thread locking compound 
(60) to shaft threads. Then install jam nut (66) and torque to 
40 ft. lbs.

It is important that the spring of the lower shaft seal (28) 
seats in the hub of the impeller (33). Rotate impeller to check 
for binding. Position gasket (36) on volute fl ange and position 
impeller and motor housing on volute (1). Position lockwasher 
(12) on cap screw (26) and screw into volute (1). Torque to 
100 in-lbs. Check for free rotation of motor and impeller.

F-3) Shaft Seal  Service:

CAUTION ! - Handle seal parts with extreme care.  
DO NOT scratch or mar lapped surfaces.

F-3.1) Disassembly and Inspection:
Outer Seal (All Units) -

 To expose shaft seal (28) for 

examination, disassemble volute and impeller as outlined in 
paragraph F-2.1. If further repair is required, remove retaining 
ring (28d), spring (28c) and rotating member (28b) from shaft 
(see Figure 6 & 7). Examine all seal parts and especially 
contact faces. Inspect seal for signs of wear such as uneven 
wear pattern on stationary members, chips and scratches 
on either seal face. 

DO NOT

 interchange seal components, 

replace the entire shaft seal  (28). If replacing seal, remove 
stationary (28a) by prying out with fl at screwdriver.

Inner Seal (DS Units Only)- 

To expose inner shaft seal 

(28) for examination, remove outer seal as outlined above.  
Remove socket head cap screws (64). Lift outer seal plate 
(29) and square-ring (27) from inner seal plate (5) see Figure 
8. If further repair is required, remove snap ring (32), retaining 
ring (28d), spring (28c) and rotating member (28b) from shaft. 
Examine as outlined in outer seal paragraph. If replacing seal, 
remove stationary (28a) by prying out with fl at screwdriver.

FIGURE 5

FIGURE 6 - DOUBLE SEAL

FIGURE 6 - SINGLE SEAL

FIGURE 7

Содержание SE51A

Страница 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario C...

Страница 2: ...18 22 SE HT SINGLE SEAL EXPLODED VIEW Fig 19 23 3SE DS DOUBLE SEAL CROSS SECTION Fig 20 24 3SE DS DOUBLE SEAL EXPLODED VIEW Fig 21 25 PARTS LIST 26 28 RETURNED GOODS POLICY 32 WARRANTY 31 WARRANTY RE...

Страница 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Страница 4: ...Filled Reservoir Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5 m 20 ft 6 1 m Cord Plug on 120 Volt 5HP 240 Volt 1 Phase Quick connect custom molded for sealing and s...

Страница 5: ...le Seal SE A SE HTA Single Seal SE AU SE HTAU Single Seal Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240...

Страница 6: ...6 Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models inches mm Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models 3SE L Single Seal 3SE DS Double Seal...

Страница 7: ...or basin that is free of hard debris like gravel stones sand or earth The sump lift station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage efflu...

Страница 8: ...rations Automatic Plug float cord into outlet then plug pump cord into float cord Manual Plug pump cord directly int outlet C 4 Electrical Connections C 4 1 Power and Control Cable The cord assembly m...

Страница 9: ...tamped on the pump identi cation plate to the available power D 2 Check Pump Rotation Before putting pump into service for the rst time the motor rotation must be checked Improper motor rotation can r...

Страница 10: ...5 3 14 4 SOW 0 570 14 5 40 80 52 00 3SE554L 0 5 600 3 60 1750 H B 1 0 3 4 14 4 SOW 0 570 14 5 77 60 89 76 3SE774L 0 75 200 240 1 60 1750 G K F 7 4 7 0 21 5 25 8 14 3 SOW 0 530 13 5 1 86 10 20 2 74 10...

Страница 11: ...he pressure does not hold then the leak must be located and repaired Pumps that have NOT had the oil drained from the Motor Housing The pressure test may be done with the oil at its normal level Remov...

Страница 12: ...volute 1 Position lockwasher 12 on cap screw 26 and screw into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service CAUTION Handle seal parts with extrem...

Страница 13: ...ing sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in...

Страница 14: ...ce station or Barnes Pumps Service department Inspect motor winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be...

Страница 15: ...eplacement parts ALWAYS furnish the following information 1 Pump serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item...

Страница 16: ...16 FIGURE 13...

Страница 17: ...17 FIGURE 13...

Страница 18: ...18 FIGURE 13 CONTIUED...

Страница 19: ...cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Страница 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...

Страница 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...

Страница 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...

Страница 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...

Страница 24: ...24 FIGURE 20 3SE DS Series Double Seal...

Страница 25: ...25 FIGURE 21 3SE DS Series Double Seal...

Страница 26: ...BS 070963 SE774L 3SE774L SE1074L 3SE1074L 029792BD 070963 3SE774DS 3SE1074DS 071354BS None SE794L SE744L 3SE794L 3SE744L SE1094L None SE1044L 3SE1094L 3SE1044L 071354BD None 3SE794DS 3SE744DS 3SE1094D...

Страница 27: ...a 084346TH 5 00 Dia 084346TJ 4 88 Dia 084346TK 4 75 Dia 084346TL 4 63 Dia 084346TM 4 50 Dia 084346TN 4 38 Dia 084346TP 4 25 Dia 084346TQ 4 13 Dia 084346TR 4 00 Dia 36 1 027344 t Gasket 39 1 014270 Pip...

Страница 28: ...ABLE LENGTH ITEM 16 120 VOLT 1 PHASE STD Temp ITEM 16 120 VOLT 1 PHASE High Temp ITEM 16 240 VOLT 1 PHASE 0 5HP STD HT ITEM 16 240 VOLT 1 PHASE 0 75 1HP STD HT ITEM 16 3 PHASE ITEM 55 OPTIONAL STD Tem...

Страница 29: ...29 Notes...

Страница 30: ...30 Notes...

Страница 31: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Страница 32: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Отзывы: