01

General Safety Information

Before installation, read the following 

instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 

bodily  injury,  death  and/or  property 

damage.  Each  Barmesa  product  is 

carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 

operating  problems,  assuring  years 
of trouble-free service. 

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation, wiring, and 

junction  connections  must  be  in 

accordance with the National Electric 

Code and all applicable state and local 
codes.  Requirements  may  vary 
depending on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 

qualified personnel only.

WARNING

D o   n o t

  p u m p 

hazardous  materials  (flammable, 
caustic,  etc.)  or  use  these  pumps  in 
water  over  95º  F. 

Do  not

  exceed 

m a n u f a c t u re r s   re c o m m e n d e d 
maximum performance, as this could 

cause the motor to overheat.

WARNING

C a r e f u l l y   r e a d 

instruction  manuals  supplied  with 
motor or engine before operating or 

servicing.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

DECONTAMINATED  PRIOR  TO 

SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 
HAZARDS  IN  HANDLING  SAID 

MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 

discharge  openings.  Do  not 

insert  fingers  in  pump  with

power  connected;  the  impeller  can 

cause serious injury.

Always  wear  eye  protection 

when working on pumps. Do 

not wear loose clothing that

may  become  entangled  in  moving 

parts.

Pumps  build  up  heat 

and  pressure  during 
operation.  Allow  time 

fo r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
pump  or  any  accessor y  items 

associated with or near the pump. Do 

not  block  or  restrict  the  discharge 
pipe/hose.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 

installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 
always  disconnect  pump 

from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

 “Caution”  indicates  a 

potentially  hazardous  situation 
which, if not avoided, MAY result in 

minor or moderate injury.

CAUTION

Do  not

  lift,  carry  or 

hang pump by the electrical 

c a b l e s.   D a m a g e   to   t h e 

electrical  cables  can  cause

DANGER

shock, burns or death. 

Never

 handle 

connected  power  cords  with  wet 

hands. Use appropriate lifting device.

 “Warning”  indicates 

an  imminenty  hazardous  situation 
which, if not avoided, MAY result in 

death or serious injury.

WARNING

 “Danger” indicates an 

imminently  hazardous  situation 

which, if not avoided, WILL result in 
death or serious injury.

DANGER

Failure  to  permanently 

ground the pump, motor and 

controls  before  connecting 

to  power  can  cause  shock,

DANGER

burns or death.

1 Phase Models

Amps:

Volts:

3 Phase Models

Amps L1-2:

Volts L1-2:

Amps L2-3:

Volts L2-3:

Amps L3-1:

Volts L3-1:

Model Number: _____________________

Serial: ____________

PHASE: ______ HP: __________________

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 

Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 

Also  record  the  Voltage  and  Current 
Readings at Startup:

WARNING

If  engine  driven,  never 

operate  in  an  enclosed 

building  or  area  where 

e x h a u s t   g a s e s   c a n

accumulate, or near a building where 

gases  can  seep  inside;  always  take 
provisions for adecuate ventilation.

Do not

 breathe exhaust 

fumes when working in the area of the 

engine.  (Exhaust  gases  are  odorless 
and deadly poison.)

WARNING

WARNING

Never  add  fuel  to  the 

tank  while  the  engine  is 

running.  Stop  engine  and 
allow to cool.

Do  not

  smoke  while  refueling  the 

engine. 

Do  not

  refuel  near  open 

flame.

barmesapumps.com

Содержание IA1-2-4

Страница 1: ...Installation Operation Maintenance Manual End Suction Centrifugal Pumps IA 2 125 HP 1750 3500 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Страница 2: ...cing the pump or any accessory items associated with or near the pump Do not block or restrict the discharge pipe hose T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water...

Страница 3: ...ally balanced SEAL Mechanical type 01 Ceramic stationary part carbon ring seal and exclusion in the rotatingpart Buna Nelastomerandstainlesssteelspring SHAFTSLEEVE Stainlesssteel O RINGS Buna N MOTOR...

Страница 4: ...xidant liquid Installation The pump should be as close as possible to the liquid to be pumped with a minimum number of couplings adapters etc in order to reduce friction on the suction side The suctio...

Страница 5: ...1 21 9 7 28 1 86 0 6 180 757 66 3 26 7 8 9 2 27 0 73 0 3 200 833 80 32 2 10 07 2 72 0 87 0 35 220 908 95 38 1 12 6 3 21 1 03 0 41 240 984 111 44 5 14 7 3 74 1 2 0 48 260 1060 128 51 3 16 9 4 3 1 38 0...

Страница 6: ...3 36 STANDARD 45 ELBOW 0 38 0 54 0 61 0 77 0 92 1 15 1 53 1 83 2 29 STANDARD TEE 1 68 2 29 2 75 3 36 4 28 5 19 6 71 8 23 10 1 ANGLE GLOBE VALVE OPEN 3 97 5 49 6 71 8 23 10 7 12 2 16 8 21 3 25 9 GLOBE...

Страница 7: ...e must be removed to allow trapped air to escape 0 39 of inclination per 3 28 ft CORRECT INCORRECT Air pocket Figure 3 Inclination Check valve completely open CORRECT D 6x D min Pressurized water Figu...

Страница 8: ...tion check valve INCORRECT CORRECT Figure 6 Discharge piping Install the foot valve at the suction pipe Figure 1 and fill with liquid the superior part of the pump s body Sometimes air is trapped insi...

Страница 9: ...tighten the nuts until the dripping decreases but not cease Frame All pumps come with factory lubricated bearings It is very important to have oil in the oil tank Use oil DTE26 Change the oil every 1...

Страница 10: ...al type pumps generally use 2 different types of flexible couplings the Lovejoy type with rubber spider and the Steelflex type F with grids buffer The first mentioned coupling requires no lubrication...

Страница 11: ...ance between the hubs and rest it on any of the covers Lubricate the slots and clearance with as much grease as possible Fill the spaces between the grid and around it with grease Remove excess Oil th...

Страница 12: ...005 0 156 4 1 8 0 028 0 005 0 02 0 007 0 188 5 1 8 0 033 0 005 0 02 0 007 0 188 6 1 8 0 038 0 005 0 02 0 007 0 188 7 1 8 0 045 0 005 0 02 0 007 0 188 8 1 8 0 052 0 01 0 03 0 01 0 25 9 1 8 0 057 0 01 0...

Страница 13: ...5 3 63 11 81 IA1 7 5 2 7 5 3515 3 213JM 13 25 IA1 10 2 10 3505 3 215JM 7 14 75 IA1 15 2 15 3530 3 254JM 8 25 19 06 IA1 20 2 20 3525 3 256JM 10 19 65 IA1 H 3 4 3 1740 3 182JM 4 5 6 88 7 5 4 5 3 63 11 8...

Страница 14: ...525 3 284JM 7 11 75 11 9 5 4 75 20 5 4 5 6 88 7 5 3 63 11 81 0 41 6 25 10 10 4 5 0 53 MODEL HP RPM PHASE FRAME A B C D E F G H IA2 2 4 2 1735 3 145JM 3 5 6 88 5 5 5 2 75 12 4 03 0 34 IA2 10 2 10 3505...

Страница 15: ...NCL ODP 4 HOLES HIGH PRESSURE CENTRIFUGAL PUMP MODEL IA3 IA3H GENERAL DIMENSIONS MODEL HP RPM PHASE FRAME A B C D E F G H IA3 3 4 3 1740 3 182JM 4 5 IA3 5 4 5 1730 3 184JM IA3 7 5 4 7 5 1750 3 213JM 5...

Страница 16: ...DEL HP RPM PHASE FRAME A B C D E F G IA4 40 2 40 3530 3 324TSC 24 10 5 IA4 50 2 50 3530 3 326TSC 25 5 12 IA4 60 2 60 3565 3 364TSC 28 11 25 IA4 75 2 75 3555 3 365TSC 29 12 25 IA4 100 2 100 3560 3 405T...

Страница 17: ...IMPELLER IA1 5 2 6 81 03140031B IMPELLER IA1 2 4 IA1 7 5 2 7 50 03140031C 5 1 SHAFT SLEEVE 30400808 6 1 SLINGER 92010014 7 1 MECHANICAL SEAL 31030131 8 1 O RING 92010033 9 1 IMPELLER S SCREW 91010345C...

Страница 18: ...10 1 11 1 12 1 ITEM QTY DESCRIPTION PART ELECTRIC MOTOR 200 230 460 ODP 3 HP 1740 RPM 3 PH FRAME 182T JM 15 HP 3530 RPM 3 PH FRAME 254T JM 20 HP 3525 RPM 3 PH FRAME 256T JM 25 HP 3530 RPM 3 PH FRAME 2...

Страница 19: ...R S SCREW FOR 15 TO 40 HP 91010351 LOCK WASHER 3 8 SS FOR 3 TO 10 HP 91010061 LOCK WASHER 1 2 SS FOR 15 TO 40 HP 91010062 IMPELLER WASHER FOR 3 TO 10 HP 30400418 IMPELLER WASHER FOR 15 TO 40 HP 304004...

Страница 20: ...30400418 IMPELLER WASHER FOR 15 TO 50 HP 30400416 SHAFT KEY FOR 3 HP TO 7 5 HP 30400631 SHAFT KEY FOR 15 TO 50 HP 30400633 13 8 STUD 3 8 16X 1 50 91010303 14 8 HEX NUT 3 8 91010413 15 8 LOCK WASHER 3...

Страница 21: ...MPELLER IA1 XH 3 4 9 19 IMPELLER IA1 XH 5 4 9 19 5 1 SHAFT SLEEVE FOR 3 TO 25 HP 30400829 6 1 SLINGER FOR 3 TO 25 HP 92010016 7 1 MECH SEAL FOR 3 TO 25 HP 31030133 8 1 O RING 92010033 9 1 IMPELLER S S...

Страница 22: ...pacity is not too much The pump is operating in the range of NPSHR If reducing ow makes the noise gone then the problem is in the point above partially close the discharge valve The bearings for wear...