background image

5. Advanced operation

34

K5902056 CORONIS FUSION 4MP / 6MP 31/10/2014

Содержание MDCC-4230

Страница 1: ...Coronis Fusion 4MP 6MP User Guide MDCC 4230 MDCC 6330 K5902056 00 31 10 2014 ...

Страница 2: ...Barco nv President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support www barco com esupport Visit us at the web www barco com Printed in Belgium ...

Страница 3: ...ugh the OSD menus 19 5 Advanced operation 21 5 1 OSD menu language 21 5 2 OSD menu automatic close function 21 5 3 Power status indicator light 21 5 4 Key indicator lights 22 5 5 Power lock function 22 5 6 DPMS mode 22 5 7 Hibernate 23 5 8 Luminance target 23 5 9 Color presets 24 5 10 Color temperature 24 5 11 Color coordinates 24 5 12 Viewing modes 25 5 13 Display functions 25 5 14 Ambient Light ...

Страница 4: ...ortant information 39 8 1 Safety information 39 8 2 Environmental information 41 8 3 Regulatory compliance information 43 8 4 EMC notice 44 8 5 Explanation of symbols 47 8 6 Legal disclaimer 49 8 7 Technical specifications 49 8 8 Technical specifications 51 8 9 Open source license information 53 2 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 5: ...n the market setting new standards for brightness and contrast even from a wide viewing angle Use the instructions in this guide to install your Coronis Fusion 4MP 6MP display and discover all these interesting features yourself CAUTION Read all the important safety information before installing and operating your Coronis Fusion 4MP 6MP Please refer to the dedicated chapter in this user guide 1 2 ...

Страница 6: ...1 Welcome 4 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 7: ...2 1 Front view 1 USB downstream connector 2 Left key 3 Right key 4 Menu key 5 Standby key 6 Power LEDs 7 Ambient light sensor The key icons are displayed above the keys adapted to the function that it is used for menu dependent See Navigating through the OSD menus page 19 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 5 ...

Страница 8: ... 2 Rear view 1 Connector compartment cover 2 24 VDC power input 3 Neck cover 4 Display stand cover 5 DisplayPort 2 video input 6 DVI 2 video input 7 DisplayPort 1 video input 8 DVI 1 video input 9 USB upstream connector 10 USB downstream connectors 6 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 9: ...covers The connector compartment cover should be removed to get access to the connectors To remove the connector compartment cover 1 Gently lift the clips at one of the handles of the connector compartment cover to release that side of the cover 2 Do the same at the other side of the cover 3 Remove the cover The display stand cover should be removed to get access to the cable routing channel To re...

Страница 10: ...he display stand is locked with a red hook to prevent damage during transportation You ll have to remove this hook before adjusting your display height position To remove the hook 1 Position the display with its rear side facing you 2 While holding the display panel pushed down pull out the red hook in the display stand 8 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 11: ...nsportation insert the short red end of the hook back into the stand of your display 3 3 Adjusting the display position Now that the height positioning system of your display is unlocked you can adjust the display position To adjust the display position 1 Tilt swivel raise and lower the display as desired K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 9 ...

Страница 12: ...s can have the same video input connected as well but only one video input is allowed on each side of your display To connect the signal cables to the display 1 Connect one head of the display controller to the DVI 1 or DisplayPort 1 connector with one of the supplied DVI or DisplayPort cables 2 Connect another head of the display controller to the DVI 2 or DisplayPort 2 connector with one of the ...

Страница 13: ...nput of your Coronis Fusion 4MP 6MP display 2 Plug the other end of the external DC power supply into a grounded power outlet by means of the proper power cord delivered in the packaging 3 6 Routing the cables To route the cables 1 Route all connected cables through the cable routing channel in the stand of your display K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 11 ...

Страница 14: ...er downward You ll hear a click sound of the cover s clips when the display stand cover is in position Pay attention that all cables stay in the cable channel while re attaching the cover To re attach the connector compartment cover 1 Slide the cover s top in position and then push the cover s bottom You ll hear a click sound of the cover s clips when the connector compartment cover is in position...

Страница 15: ...hould mount the panel in landscape position Portrait position is pos sible but not supported Overview The panel standard attached to a stand is compatible with the VESA 100 mm standard Thus it can be used with an arm that is approved by VESA This chapter shows you how to release the panel from the stand and how to attach it to an arm If you re not using an arm you can skip this chapter 1 Gently pu...

Страница 16: ...h the panel firmly to the arm using 4 screws M4 x 10 mm WARNING Never move a display attached to an arm by pulling or pushing the display itself Instead make sure that the arm is equipped with a VESA approved handle and use this to move the display Please refer to the instruction manual of the arm for more information and instructions 3 9 First time starting up Overview You are now ready to start ...

Страница 17: ...is finished Your Coronis Fusion 4MP 6MP display will be running in a basic video mode at a de fault refresh rate when first time starting up If you are using a Barco display controller please consult the dedicated user guide available on the system CD to install the drivers software and documentation When this is done your display will automatically detect the connected video input signal s and ap...

Страница 18: ...3 Display installation 16 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 19: ...usage A good screen saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated change the image content regularly to avoid image retention of the static elements Understand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manu...

Страница 20: ...Key in dicator lights page 22 for detailed instructions on how to do this 4 3 Standby switching About standby switching The connected power supply also provides a switch that can be used to turn the power completely off To use the display please make sure to switch on this power supply This can be done by pushing the on off switch on the power supply into the position Switching on the display whil...

Страница 21: ...s are taken within the following 90 seconds the OSD will disappear again The OSD menu auto exit function can be disabled in the OSD menu Please refer to OSD menu automatic close function page 21 for detailed instructions on how to do this 4 5 Navigating through the OSD menus How to navigate through the OSD menus Navigating through the OSD menus can be done by Use the left right keys to move throug...

Страница 22: ...4 Daily operation Cancel Standby IEC 60417 5009 20 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 23: ...sed To enable disable the OSD menu automatic close function 1 Bring up the OSD main menu 2 Navigate to the Configuration User Interface Menu menu 3 Enter the Automatic Close submenu 4 Select Enabled Disabled as desired and confirm 5 3 Power status indicator light About the power status indicator light By default when the display is switched on the power status indicator light is dimmed This behavi...

Страница 24: ...ain menu 2 Navigate to the Configuration User Interface Controls menu 3 Enter the Power Lock submenu 4 Select Enabled Disabled as desired and confirm 5 6 DPMS mode About DPMS mode Enabling the Display Power Management System DPMS mode on your display will optimize its diagnos tic lifetime by automatically switching off the backlight when the display is not used for a specified period of time By de...

Страница 25: ...Disabled as desired and confirm To specify the hibernate timeout 1 Bring up the OSD main menu 2 Navigate to the Configuration Power Management menu 3 Enter the Hibernate Timeout submenu 4 Set the timeout value as desired and confirm 5 8 Luminance target About the luminance target The luminance target of your Coronis Fusion 4MP 6MP is adjustable over a predefined range When you change the luminance...

Страница 26: ...esets and confirm 5 10 Color temperature About color temperature It is possible to change the color temperature of your display Color temperature can only be changed on your display when color presets is set to user Therefore please refer to Color presets page 24 to do this To change the color temperature 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration Color Settings menu ...

Страница 27: ...witch the viewing mode without having to enter the OSD menu touch the left and right key the two leftmost buttons at the same time during normal operation As the Coronis Fusion 4MP 6MP is intended to be used in a diagnostic environment the diagnostic mode should always be selected To select a viewing mode 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration menu 3 Enter the Vie...

Страница 28: ... to replace a CRT display with a gamma of 1 8 or 2 2 respectively To select a display function 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration menu 3 Enter the Display Function submenu 4 Select one of the available display functions and confirm 5 14 Ambient Light Compensation ALC About ALC Ambient Light Compensation ALC can only be enabled on your display when the DI COM d...

Страница 29: ...ration executed yet No other information is visible DICOM Calibration Status Calibration executed When the calibration is executed the following extra information is shown Backlight runtime elapsed since latest calibration display function ambient light compensation reading room Display function Shows the current display function Ambient Light Compensation Shows the ambient light compensation stat...

Страница 30: ...8 Reset DICOM calibration About reset DICOM calibration It is possible to restore the original not corrected DICOM curve To reset the DICOM calibration 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration Embedded QA menu 3 Enter the DICOM preferences submenu 4 Select reset DICOM calibration to restore the original not corrected DICOM curve 5 19 DICOM error threshold About DICO...

Страница 31: ...his setting has the lowest maximum ambient light CT MR NM Corresponds to light conditions in diagnostic reading rooms for computed tomography magnetic resonance or nuclear medicine scans Staff Office Corresponds to light conditions in office rooms Clinical Viewing Room Corresponds to light conditions in diagnostic reading rooms for clinical viewing Emergency Room Corresponds to light conditions in...

Страница 32: ...ronis Fusion 4MP 6MP automatically detects the number of video input signals connected at taches them to the correct display side and applies the correct video settings to it resolution video encod ing mode refresh rate However it may be needed to manually select the video input signal s to be displayed on a certain display side or to adjust certain video settings yourself The start to this is sel...

Страница 33: ...e source selection mode should be set to allow this Please refer to Image source selec tion modes page 30 to do this About input configuration Depending on the image source selection mode following inputs can be configured Menu Image source selection mode Input Signal 1 Image Source Connector configuration DisplayPort 1 2 DVI 1 2 for the input signal Left Input Signal Connector configuration Displ...

Страница 34: ...e No Conversion Use Red Channel This mode is intended for grayscale displays where gray is sent over the red channel Use Green Channel This mode is intended for grayscale displays where gray is sent over the green channel Use Blue Channel This mode is intended for grayscale displays where gray is sent over the blue channel To manually select a grayscale conversion mode 1 Bring up the OSD main menu...

Страница 35: ... 4 Select Resolution Refresh Rate Preferred Orientation or Color Depth 5 Select one of the available settings and confirm 5 28 Display info About display info Your display serial number color type native resolution firmware versions etc are available in a dedi cated submenu of the OSD menu To retrieve info about your display 1 Bring up the OSD main menu 2 Navigate to the About this Display menu to...

Страница 36: ...5 Advanced operation 34 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 37: ...ol solvents at higher concentration 5 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with steel thread CAUTION Take care not to damage or scratch the front glass or LCD Be careful with rings or other jewelry and do not apply excessive pressure on the front glass or LCD CAUTION Do...

Страница 38: ...6 Cleaning your display 36 K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 ...

Страница 39: ...kaging 1 2 3 4 5 6 7 8 Image 7 1 Repack instructions 1 Box 5 Coronis Fusion 4MP 6MP display 2 System CD Documentation CD and User guide 6 Top buffer 3 Bottom buffer 7 Display controller box 4 Power supply 8 Cables video USB power K5902056 CORONIS FUSION 4MP 6MP 31 10 2014 37 ...

Страница 40: ...er supply in the dedicated cavity of the bottom buffer 5 Put the Coronis Fusion 4MP 6MP display in its original bag and place it in the box with its panel facing downwards 6 Put the top buffer on top of the display 7 When applicable slide the display controller box in the dedicated cavity of the buffers 8 Put all cables video USB power in their original bag and slide them in the dedicated cavity o...

Страница 41: ... patient care equipment Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely no applied part The equipment may not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Power connection Equipment with external 24 VDC power ...

Страница 42: ...other closed location heed the necessary space between the set and the sides of the cupboard Installation Place the device on a flat solid and stable surface that can support the weight of at least 3 devices If you use an unstable cart or stand the device may fall causing serious injury to a child or adult and serious damage to the device This apparatus conforms to MDCC 6330 CE0120 MDD 93 42 EEC A...

Страница 43: ... barco com en AboutBarco weee Turkey RoHS compliance Türkiye Cumhuriyeti AEEE Yönetmeliğine Uygundur Republic of Turkey In conformity with the WEEE Regulation 中国大陆 RoHS Chinese Mainland RoHS 根据中国大陆 电子信息产品污染控制管理办法 也称为中国大陆RoHS 以下部分列出了Barco产品 中可能包含的有毒和 或有害物质的名称和含量 中国大陆RoHS指令包含在中国信息产业部MCV标准 电子信息产品中有毒物质的限量要求 中 According to the China Administration on Control of Pollution Caused by Electronic Informatio...

Страница 44: ...aterials used for this part is above the limit requirement in SJ T11363 2006 在中国大陆销售的相应电子信息产品 EIP 都必须遵照中国大陆 电子信息产品污染控制标识要求 标准 贴上环保使用期限 EFUP 标签 Barco产品所采用的EFUP标签 请参阅实例 徽标内部的编号使用于制 定产品 基于中国大陆的 电子信息产品环保使用期限通则 标准 All Electronic Information Products EIP that are sold within Chinese Mainland must comply with the Electronic Information Products Pollution Control Labeling Standard of Chinese Mainland mark...

Страница 45: ...imits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no gua...

Страница 46: ...hose directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes This Coronis Fusion 4MP 6MP complies with appropriate medical EMC standards on emissions to and interference from surrounding equipment Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interf...

Страница 47: ...T 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5s Mains power quality should by that of a typical commercial or hospital environment If the user of the Coronis Fusion 4MP 6MP requires continued operation during power mains interruptions it is recommended that the Coronis Fusion 4MP 6MP be powered from an uninterruptible power supply or a battery Power frequency ...

Страница 48: ...ser of the Coronis Fusion 4MP 6MP can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the Coronis Fusion 4MP 6MP as recommended below according to the maximum output power of the communications equipment 3 Field strengths from fixed transmitters such as base stations for radio cellular cordless tel...

Страница 49: ...owing symbols nonrestrictive list Indicates compliance with the Directive 93 42 EEC as Class I device Indicates compliance with the Directive 93 42 EEC as Class II device Indicates compliance with Part 15 of the FCC rules Class A or Class B Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada and US Indicates t...

Страница 50: ...tes the DisplayPort connectors on the device Indicates the manufacturing date Indicates the temperature limitations6 for the device to safely operate within specs Indicates the device serial no Warning dangerous voltage Caution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste Electrical and Electronic...

Страница 51: ...ucts are subject to change without notice Trademarks All trademarks and registered trademarks are property of their respective owners Copyright notice This document is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical including photocopying taping or information storage and retriev...

Страница 52: ...z Housing color Black Silver Video input signals DVI D Dual Link 2x DisplayPort 2x Video inout terminals NA USB ports 1 upstream endpoint 3 downstream USB standard 2 0 Power requirements nominal 100 240V Power consumption nominal 105W Power save mode Yes Power management DVI DMPM DP DMPM Dot clock 280 MHz OSD languages English German French Dutch Spanish Italian Portugese Polish Russian Swedish Ch...

Страница 53: ... USA UL CSA adaptor plug NEMA 5 15P Chinese CCC USB 2 0 cable Supplied accessories External power supply Optional accessories None QA software MediCal QAWeb Units per pallet NA Pallet dimensions W x H NA Warranty 5 years Operating temperature 0 C to 35 C 15 C to 30 C within specs Storage temperature 20 C to 60 C Operating humidity 8 80 non condensing Storage humidity 5 95 non condensing Operation ...

Страница 54: ...onsumption nominal 105W Power save mode Yes Power management DVI DMPM DP DMPM Dot clock 280 MHz OSD languages English German French Dutch Spanish Italian Portugese Polish Russian Swedish Chinese simplified Japanese Korean Arabic Dimensions with stand W x H x D Portrait NA Landscape 731 x 580 676 x 265 mm Dimensions w o stand W x H x D Portrait NA Landscape 731 x 485 x 141 mm Dimensions packaged W ...

Страница 55: ...onents released under an Open Source license A copy of the source code is available on request by contacting your Barco customer support representative EACH SEPARATE OPEN SOURCE SOFTWARE COMPONENT AND ANY RELATED DOCUMENTA TION ARE PROVIDED AS IS WITHOUT EXPRESS OR IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU LAR PURPOSE IN NO EV...

Отзывы: