R5909934 /00
E2 Lite and EC-40
318
C.1 Troubleshooting List
Problem solving
Problem
Possible cause
Remedy
Event Master unit doesn't start
The Power supplies are not
connected to a valid power source
Make sure that at least one power
supply is connected to a valid
power source.
Make sure that the supplies are well
inserted in their slots. Remove the
power cord and apply a little
pressure by using the handle until
both supplies are fully inserted.
Corrupt configuration data is in the
system.
Press and hold the
SEL
and
ESC
keys while applying power to the
unit. Release these keys when a
menu appears asking to Factory
Reset the unit. Perform the Factory
Reset and the unit will boot
normally.
One of the Power Supplies is not
coming on
If the input AC power LED on the
Power supply is off, then the supply
is not receiving a valid AC power
Check the AC power cable and
ensure that the unit is connected to
a valid power source.
If the input AC power LED is green
but the output DC power LED is off
or if the status LED is amber, then
the supply is not producing valid DC
output power
If the other Power supply is
functioning normally, swap it with
the supply that doesn't work. If the
problem follows the power supply,
then the you need to replace the
power supply. If the problem stays
with the slot, then the fault possibly
lies with the System Power card.
Contact your local Barco customer
service support for further
assistance.
All or most images are unstable or/
and noisy
Temperature issue
Operating ambient temperature
must be higher than 0°C (32°F)
and lower than 40°C (104°F).
Run the board diagnostics in order
to detect errors.
Leave sufficient front and rear
clearance to ensure that airflow
through the Event Master unit is not
restricted.
Clean the EMI filter, if an EMI filter
is present.
A specific image is unstable or/and
noisy
Bad Input, output, VPU or
motherboard card
Run the board diagnostics in order
to detect errors. If the board
diagnostics doesn
’
t detect any
errors proceed to the next step.
From the GUI change the output
card from which the image is
derived. If the problem persists,
then the issue is not with the output
card. Continue by switching the
input source to a different input
card. If the issue persists then the
issue is not with input card. If the
input and output cards have been
ruled out, then the issue is either
with a VPU card or with the
Содержание Event Master E2 Lite
Страница 1: ...ENABLING BRIGHT OUTCOMES User s Guide E2 Lite and EC 40...
Страница 10: ...R5909934 00 E2 Lite and EC 40 10...
Страница 14: ...R5909934 00 E2 Lite and EC 40 14 Introduction...
Страница 18: ...R5909934 00 E2 Lite and EC 40 18 Safety...
Страница 32: ...R5909934 00 E2 Lite and EC 40 32 General...
Страница 46: ...R5909934 00 E2 Lite and EC 40 46 Hardware orientation...
Страница 168: ...R5909934 00 E2 Lite and EC 40 168 EM GUI orientation...
Страница 208: ...R5909934 00 E2 Lite and EC 40 208 Controller Orientation...
Страница 214: ...R5909934 00 E2 Lite and EC 40 214 Controller Configuration...
Страница 220: ...R5909934 00 E2 Lite and EC 40 220 Controller Operation...
Страница 226: ...R5909934 00 E2 Lite and EC 40 226 13 2 Process Overview Flow chart Image 13 2 E2 Lite Maintenance...
Страница 284: ...R5909934 00 E2 Lite and EC 40 284 E2 Lite Maintenance...
Страница 289: ...289 R5909934 00 E2 Lite and EC 40 Environmental Information 15...
Страница 300: ...R5909934 00 E2 Lite and EC 40 300 Specifications...
Страница 316: ...R5909934 00 E2 Lite and EC 40 316 Remote Control Protocol...
Страница 317: ...317 R5909934 00 E2 Lite and EC 40 Troubleshooting C...
Страница 320: ...R5909934 00 E2 Lite and EC 40 320 Troubleshooting...
Страница 329: ...R5909934 00 E2 Lite and EC 40 329 Index...