Encore VPx Installation Guide • 08-0311105-00 Rev 00
11
båÅçêÉ=smñ=fåëí~ää~íáçå=dìáÇÉ
VPx Hardware
14) Unit ID Selector
One 16-position selector (with physical digits
0
-
15
) is provided for setting an
unique
ID
on a VPx The selector enables you to assign logical IDs
1
to
16
.
By default, a VPx is configured as an
DHCP Client
, and it automatically obtains
an IP address when it sees a
DHCP Server
. Controller Models SC and LC are
configured (by default) as DHCP Servers.
15) Serial Port
One 9-pin D connector is provided for RS-232 serial communications with VPx.
16) AC Connector
One
AC Connector
is provided to connect the VPx to your AC source.
See the “
Program Output Notes
” section on page 14 for more information on VPx outputs.
Note
Physical digit
0
equates to logical ID
16
.
Note
Always ensure that each VPx has a unique
ID
. During setup,
the
ID
is used during various configuration procedures.
Note
Using the
Miscellaneous Menu
, you can re-define IDs using
numbers
17
-
32
. In Chapter 5 of the
Encore Presentation
System User’s Guide
, refer to the “
Miscellaneous Menu
”
section for details.