Code 20531:
“
LDM 1-3
–
LLS bank 6 drain voltage too high
”
For this error the same troubleshooting table can be applied to as for code
20323
:
“
LDM 1
–
LLS bank 1 drain
voltage too high
”
.
Code 20535:
“
LDM 1-3
–
LLS bank 4 current too high
”
For this error the same troubleshooting table can be applied to as for code
20335
:
“
LDM 1-2
–
LLS bank 1
current too high
”
.
Code 20539:
“
LDM 1-3
–
LLS bank 5 current too high
”
For this error the same troubleshooting table can be applied to as for code
20335
:
“
LDM 1-2
–
LLS bank 1
current too high
”
.
Code 20543:
“
LDM 1-3
–
LLS bank 6 current too high
”
For this error the same troubleshooting table can be applied to as for code
20335
:
“
LDM 1-2
–
LLS bank 1
current too high
”
.
Code 20559:
“
LDM 1-3
–
LLS bank 4 temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20359
:
“
LDM 1-2
–
LLS bank 1
temperature too high
”
.
Code 20560:
“
LDM 1-3
–
LLS bank 4 temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20360
:
“
LDM 1-2
–
LLS bank 1
temperature sensor shorted
”
.
Code 20561:
“
LDM 1-3
–
LLS bank 4 temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20361
:
“
LDM 1-2
–
LLS bank 1
temperature sensor open
”
.
Code 20565:
“
LDM 1-3
–
LLS bank 5 temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20359
:
“
LDM 1-2
–
LLS bank 1
temperature too high
”
.
Code 20566:
“
LDM 1-3
–
LLS bank 5 temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20360
:
“
LDM 1-2
–
LLS bank 1
temperature sensor shorted
”
.
Code 20567:
“
LDM 1-3
–
LLS bank 5 temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20361
:
“
LDM 1-2
–
LLS bank 1
temperature sensor open
”
.
Code 20571:
“
LDM 1-3
–
LLS bank 6 temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20359
:
“
LDM 1-2
–
LLS bank 1
temperature too high
”
.
Code 20572:
“
LDM 1-3
–
LLS bank 6 temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20360
:
“
LDM 1-2
–
LLS bank 1
temperature sensor shorted
”
.
Code 20573:
“
LDM 1-3
–
LLS bank 6 temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20361
:
“
LDM 1
–
LLS bank 1
temperature sensor open
”
.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...