R5906848 /04
DP2K SLP Series
144
10
8
9
Image 11-6
9.
Install the Mask plate and Rod heatsink. See procedure
“
Installing the Mask plate and Rod heatsink
, page
The Integration Rod has to be readjusted after replacement.
11.5 Installing the Mask plate and Rod heatsink
CAUTION:
Take into account that the Mask plate and Rod heatsink are mounted very close to the
Rod entrance. The Rod is extremely fragile! Avoid touching the Rod at all times. An minor collision
is sufficient to cause irreversible damage to the Rod.
Required tools
•
TX10 Torx driver.
•
Cotton gloves.
•
3mm Allen wrench.
How to install the Mask plate and Rod heatsink onto the Light Pipe entrance?
1.
Install the Rod heatsink as illustrated (reference 7 Image 11-7). Fasten the Rod heatsink with two Torx
countersunk
head screws (reference 6 Image 11-7). Use a TX10 Torx driver.
Note:
The Rod heatsink is provided with a temperature sensor (reference 1). This temperature sensor
must facing the Light Pipe as illustrated in Image 11-8.
Caution:
Ensure that the Rod heatsink does NOT touches the Rod!
Caution:
Any contact with the integration rod may cause damage.
2.
Install the Mask plate (reference 5 Image 11-7) with the
shiny side facing outwards
as illustrated. Use the
Mask plate with engraved number
R8761960
.. Fasten with two Torx
countersunk
head screws (reference 6
Image 11-7). Use a TX10 Torx driver.
Caution:
Ensure that the Mask plate does NOT touches the Rod!
Tip:
Wear cotton gloves to prevent fingerprints on the Mask plate.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...