R5906848 /04
DP2K SLP Series
168
These measured color coordinates are references for the projector and will be entered so that the projector
knows how its colors are projected on the screen. This reference measurement (MCGD), together with the
delivered gamut file (TCGD) of the film will introduce a color correction so that the film will be projected with
the desired color target.
x
y
G
t
C
t
Y
t
M
t
R
t
B
t
Image 15-2: Correction of native color gamut towards desired color gamut (electronic correction)
Electronic correction
The electronic correction adapts the native color gamut towards the desired (target) color gamut (e.g. DC28_
DCI_Xenon.TCGD). This correction is introduced by the DMD drivers and is also called
‘
P7 correction
’
. The
electronic correction takes place once the MCGD file of the projector is mapped with the TCGD file of the film.
Influence of aspect ratio
The aspect ratio of the projected image could have a small influence upon the measured xy coordinates.
Therefore, it's recommended to save the xy coordinates per aspect ratio in separate MCGD files.
CAUTION:
Prior to start with color gamut calibration ensure that the white point calibration is
finalized successfully. See
Color gamut calibration procedure
1.
Check if the white point calibration is done. If not see
2.
Setup the ambient light conditions
as it should be during the play out of the movie. (e.g. only the stairs and
emergency exit lighting is switched on).
Note:
In an optimal setup less than 1% of light from any other source than the light from the projector
should illuminate the screen.
3.
Sequentially measure and enter the xy coordinates
of the three primary colors (red, green, blue) and full
white. Use therefore the Communicator. Go to
Installation
>
Color calibration
>
Measure native colors
. For
detailed instructions see user guide of the Communicator.
Caution:
Ensure that the correct projection mode is selected: 2D or External 3D.
Caution:
In case of 3D, measure the xy coordinates once through the left eye glass of the 3D goggles
and once through the right eye glass.
Tip:
When using the wizard for white point calibration you can immediately proceed with the electronic
correction.
4.
Once all xy coordinates are measured and entered proceed by saving all measured values into a MCGD file.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...