18.4 Replacement of the ICP board
WARNING:
Disconnect the power cord of the projector from the power net and wait a few minutes
(to discharge the capacitors) prior to starting this procedure.
CAUTION:
Wear a wrist band which is connected to the ground while handling the electrostatic
discharge sensitive parts.
Required tools
PH2 Phillips screwdriver.
How to replace the ICP board of the projector?
1.
Release the two retaining screws (reference 1) at the front of the ICP board. Use a PH2 Phillips screwdriver.
2.
Pull the ICP board out of its compartment.
3.
Gently insert the ICP board in the guides of the ICP compartment as illustrated. Push it completely in.
Caution:
Ensure that the both sides of the ICP board are captured by the guides inside the ICP
compartment.
4.
Fasten the two screws at the front side of the ICP board (reference 1). Use a PH2 Phillips screwdriver.
5.
Reconnect the power cord and switch on the projector.
6.
Check if the latest firmware of the ICP board is installed. If not, upgrade to the latest version. See
Communicator User Guide.
7.
Is there a full backup clone or backup including the TI specific files available?
1.
If available:
•
Reinstall the clone file. See Communicator User Guide chapter
“
Installation
”
where 'cloning' is
explained.
•
Upload the LUT-SCC file into the projector file system. (e.g. 1110351581.LUT-SCC). See procedure on
page 155.
•
Activate the LUT-SCC file. See procedure on page 156.
2.
If NOT available: perform the same additional actions as for a new Light Processor (see
“
18.5 Replacement of the RTC battery of the ICP
board
Required tools
Phillips screw driver
Required parts
All parts are included in kit R8766526K (battery cover, coin cell battery BR2330 and a pair of gloves).
How to replace
1.
Put on the gloves.
2.
Remove the ICP board from the card cage. See chapter
“
Removing a board in the card cage
”
.
3.
Carefully put the ICP board on a table.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...