8.1 Check cooling liquid level & cooling integrity
What should be done ?
The Light Source is liquid cooled. Running with a low liquid cooling level may damage the cooling circulation
pump. Moreover, the cooling capacity may be strongly reduced which can result in higher temperatures inside
the projector. These higher temperatures may cause an interruption of your film projection as the light source
can be switched off by the software as a precaution.
To avoid this problem, we strongly advise to check the cooling liquid level at least once every 12 months.
WARNING:
Due to the closed system, the cooling liquid level should not decrease, or only
decrease in small amounts over time. Dramatic loss of cooling liquid may indicate a potential
leakage in the system. Check the light source compartment on both the front and back ends of the
light source for visual signs of leakage (dried cooling liquid turns into a crystallized white powder).
Since servicing of the light source cooling system is not supported, if a leakage occurs, the cooling
pump is damaged or similar damage occurs to the cooling system, the entire light source will need
to be replaced.
How to check the liquid level?
1.
Remove the side cover on the light processor side,
Removal and installation of the projector covers
”
, page
2.
Look through at the cooling reservoir on the light source and check the liquid cooling level in the light source.
Image 8-1: Cooling liquid check
If the current liquid cooling level is somewhere between
120
and
600
, then no action should be taken.
If the current liquid cooling level is lower than
120
, start the refill procedure.
8.2 Cooling liquid refill
WARNING:
This procedure may only be performed by qualified technical service personnel.
CAUTION:
Be careful when refilling the reservoir. Make sure not to spill any cooling liquid on the
control boards located next to the reservoir. If any liquid is spilled, make sure to clean it up
immediately by using a dry cloth.
Содержание DP2K SLP Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Страница 4: ......
Страница 10: ...R5906848 04 DP2K SLP Series 10 ...
Страница 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Страница 24: ...R5906848 04 DP2K SLP Series 24 General ...
Страница 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Страница 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Страница 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Страница 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Страница 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Страница 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Страница 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Страница 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Страница 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Страница 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Страница 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Страница 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Страница 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Страница 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Страница 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Страница 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Страница 409: ...R5906848 04 DP2K SLP Series 409 ...