XIRING – Ingenico Healthcare / eID – Baracoda orKan ‘barcode’ – User Guide v1.5
26/35
An ‘
Idle Menu
’ is displayed. Navigate in it with left or right button and select ‘
Main
Menu
’ by pressing the trigger button:
c.
Terminal info
By pressing the “INFO’ icon available on the ‘
Main Menu
’, the user will have access to
main information of the terminal :
o
BT.name: xxxx.
By default, ‘xxxx’ is “BOK_bbbb” with ‘bbbb’, the value of last 4 digits of BDA
o
FW package: v.x.x.xx.xx
o
Batt level: xx %
o
BDA: XX:XX:XX:XX:XX:XX (Bluetooth Device Address)
2)
Application: Introduction
All embedded applications in the orKan terminal can be defined by the following list of
requirements (that they have to to comply with during its creation):
o
Scenario & action(s)
: a user application is an execution of action(s) sequence ; in other
word, it is a
scenario
.
o
Scenario start & end
: a scenario starts with a data capture and ends by the processed
data being sent (
in Real Time mode
: sent to the configured host;
in Batch mode:
sent to
flash memory)
o
There is only one active scenario at a time.
o
Application Field Separator
: an action can produce a result. Each result is concatenated
to the captured data. Each concatenated part is separated by a delimiter defined by the
customer (Application Field separator).
o
To quit the user application:
(scenario’s loop (from end to beginning)), the left&right
buttons have to be pressed together; next select the “Main Menu” option.
Of course scenarios (that is a sequence list of actions) can be defined by the customer (with
the help of the Baracoda Desktop Manager software). This can be done by either modifying
the existing scenarios or adding new ones (depending of the license rights).