XIRING – Ingenico Healthcare / eID – Baracoda orKan ‘barcode’ – User Guide v1.5
19/35
3)
Barcode Symbology Settings
You can enable/disable/modify any type of barcode symbology with both the Baracoda
Desktop Manager software (
only for 1D and Laser terminals
) or with the Programming
Guide.
4)
Data format
The general format of data sent by the orKan terminal to the remote host is shown on the
following table:
where:
a.
Baracoda Header
It is a proprietary data encapsulation header. The user will need to activate the
Baracoda header in 2 cases:
-
to be able to receive data in the Baracoda Desktop Manager.
-
to use the “No data loss” mode (and application acknowledgement).
You can configure the Baracoda header with the Baracoda Desktop Manager software
(on the General tab of the Device Settings module). The Baracoda header is enabled by
default.
b.
Application Reference
This data corresponds to the identifier of the currently active application. This option is
disabled by default.
c.
Data Nature
This byte can be used to identify the nature of received data (barcode, RFID, ...). The
data nature byte is not active by default.
d.
TimeStamp
Timestamp can be configured (enable/disable, synchronize the orKan real time clock
with the PC) with the Baracoda Desktop Manager and by configuration barcodes.
Timestamp format is the following: YYMMDDhhmmss, where
YY: YEAR
MM: MONTH DD: DAY
hh: Hours
mm: Minutes ss: Seconds
Header
App ref
Data
nature
Time-
stamp
Data
prefix
Capture
prefix
Symbology/
Protocol prefix
AIM/
Protocol
ID
Processed
data
Symbology
/Protocol
suffix
Capture
suffix
Data
suffix
1 byte
1 byte
1 byte
12 bytes
0-32
bytes
0-32
bytes
0-4 bytes
0, 2 or 3
bytes
-
0-4 bytes
0-32
bytes
0-32
bytes
Frame Field Separator
(1Byte)