background image

MSC..-1S..E 

Supplement: MINI-SCREEN Models with Selectable Trip/Latch Output

 

 

P/N 68980     

 

Banner Engineering Corp. • Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

TB1

MSCE

TB1

CNC
AUX

MPCE

2

MPCE 1 MPCE 2

MPCE 1

Optional hookup

for Power Monitoring

EDM as described

in primary manual.

MPCE 2

L (V ac) or + (V dc)

N (V ac) or – (V dc)

PE

Earth Ground

*Arc Suppressor,
see warning at left.

TB1

MSA-RM-2

Relay Module

FSD1

FSD2

K1

K2

SSD

SSD

TB2

TB2

TB4

See Figure 5

Mon a

Mon b

Jumper Mon a and
Mon b for no
EDM monitoring

KEY 1

KEY 2

MSC..-1S3E

MINI-SCREEN Control Box

AUX

MPCE1

MPCE2

TB1

MPCE

1

L (V ac)

or

+ (V dc)

N (V ac)

or

– (V dc)

Machine

Control

Circuit

See Sections 2.10(s) 
and 3.2.1.1(s) on the 
installation of the 
Key Reset switch.

*

*

*

Figure 23 Replacement 

Figure 23b(s).  Generic MaAchine Interface, MINI-SCREEN MSC..-1T3E Systems with the MSA-RM-2 relay pack

WARNING . . . 

User must comply with all product manuals 
and relevant regulations.

WARNING . . . 

All MINI-SCREEN System output 
contacts
 (FSD1, FSD2, and SSD) 
must be used. The generalized wiring 
configuration shown here is provided 
only to illustrate the importance of proper 
installation. The actual details of wiring of 
the MINI-SCREEN system to any particular 
machine is solely the responsibility of the 
installer and end user.

WARNING . . . 

 Arc 

Suppressors

If arc suppressors are used, they must 
be installed as shown across the coils 
of the safety relays. Never install arc 
suppressors directly across the output 
contacts of any safeguarding device.

Содержание MSC 1S Series

Страница 1: ...o include Trip Latch output select switches and the addition of a one channel External Device Monitoring EDM input The primary instruction manual for these control boxes is Banner p n 39022 The inform...

Страница 2: ...nstruction manual and Section 3 4 s in this supplement Trip Output Upon power up when the control box is configured for Trip Output the FSD and SSD outputs will automatically close once power is appli...

Страница 3: ...ust be jumpered if EDM is not used If the MINI SCREEN is set for No Monitoring the user must ensure that any single failure of the external devices will not result in a hazardous condition and will pr...

Страница 4: ...ust be eliminated or reduced to acceptable levels as determined by the user by employing supplemental safeguarding One solution is to combine perimeter guarding with area guarding so that an individua...

Страница 5: ...internal lockout condition See Sections 2 2 s 2 10 s and 3 2 1 1 s for Warnings and further information Section 3 5 2 Replacement 3 5 2 s External Device Monitoring and System Power Temporary Connecti...

Страница 6: ...ght NOTE See Sections 2 10 s and 3 2 1 1 s on the installation of the Key Reset switch Figure 23 Replacement Figure 23a s Generic Machine Interface MINI SCREEN MSC 1S2E Systems with the MSA RM 1 relay...

Страница 7: ...Circuit See Sections 2 10 s and 3 2 1 1 s on the installation of the Key Reset switch Figure 23 Replacement Figure 23b s Generic MaAchine Interface MINI SCREEN MSC 1T3E Systems with the MSA RM 2 relay...

Страница 8: ...eplacement 3 5 6 s Auxiliary Relay Output The MSC 1S E controller has an Auxiliary Monitor Relay output See Figure 5 in the primary manual for operating status condition and output status The action o...

Страница 9: ...ossible to reset the MINI SCREEN in this condition If the measurement is approximately 0V dc there is likely a closed circuit The problem is likely a slow or sticky MPCE causing the EDM input to close...

Страница 10: ...ent Status LEDs Diagnostic Indicator LEDs Controller Module Assembly Red Intermittently flashing 4 red LED indicates presence of optical or electrical noise Green LED indicator is always ON except whe...

Страница 11: ...e contacts of the monitored device must be capable of switching 15 to 50V dc at 20 to 100 mA Output Configuration FSD1 FSD2 and SSD Replaces Output Configuration category Relays have forced guided con...

Страница 12: ...Banner Engineering Corp warrants its products to be free from defects for one year Banner Engineering Corp will repair or replace free of charge any product of its manufacture found to be defective a...

Отзывы: