MSC..-1S..E
Supplement: MINI-SCREEN Models with Selectable Trip/Latch Output
P/N 68980
11
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Glossary Addition
External Device Monitoring (EDM)
A means by which a safety device monitors devices that may be controlled by the safety
device. Also known as “MPCE monitoring” and “relay back-checking.”
Replacement Control Box Specifications Categories
EDM Input
(Replaces “Test
Input” category)
Terminals must be closed before the controller attempts to reset (close)
the FSD outputs after clearing an interruption of the defined area. The
EDM input should open when the FSD outputs close (a clear condition),
but this is not required. The EDM input must be closed within 200
milliseconds of the FSD outputs opening (a blocked condition) or a
lockout will occur.
The contacts of the monitored device must be capable of switching 15 to
50V dc at 20 to 100 mA.
Output Configuration
(FSD1, FSD2, and
SSD)
(Replaces “Output
Configuration”
category)
Relays have forced-guided contacts.
FSD1 and FSD2:
MSC..-1S2E: 250V ac at 4A max (resistive load)
MSC..-1S3E: 250V ac at 6A max (resistive load)
SSD: 250V ac at 4A max (resistive load)
CNC AUX (MSC..-1S3E): 250V ac at 6A max (resistive load),
complementary normally closed
Mechanical life: 10,000,000 operations (minimum)
Electrical life: 100,000 operations (typical @ 1.0kVA switched power,
resistive load)
Arc suppression is recommended when switching inductive loads; see
Warning in Figure 23(s).
Model
Description
For Control Box Models
MSAS-1E
Microprocessor control module
MSC..-1S2E/-1S3E
MSA-RM-1
Replacement relay module
MSC..-1S2E
MSA-RM-2
Replacement relay module
MSC..-1S3E
MSA-PSA-1
Replacement power supply
MSCA-1S2E/-1S3E
MSA-PSB-1
Replacement power supply
MSCB-1S2E/-1S3E
MSA-PST-1
Replacement power supply
MSCT-1S2E/-1S3E
Section Addition
Replacement Parts, MINI-SCREEN Systems