MSC..-1S..E
Supplement: MINI-SCREEN Models with Selectable Trip/Latch Output
P/N 68980
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
TB1
MSCE
TB1
MPCE
2
MPCE 1 MPCE 2
MPCE 1
Optional hookup
for Power Monitoring
EDM as described
in primary manual.
MPCE 2
L (V ac) or + (V dc)
N (V ac) or – (V dc)
PE
Earth Ground
TB1
MSA-RM-1
Relay Module
FSD1
FSD1
FSD2
FSD2
SSD
SSD
TB2
TB2
TB4
See Figure 5
Mon a
Mon b
Jumper Mon a and
Mon b for no
EDM monitoring
KEY 1
KEY 2
MSC..-1S2E
MINI-SCREEN Control Box
AUX
MPCE1
MPCE2
TB1
MPCE
1
L (V ac)
or
+ (V dc)
N (V ac)
or
– (V dc)
Machine
Control
Circuit
*Arc Suppressor,
see warning at right
NOTE: See Sections
2.10(s) and 3.2.1.1(s) on
the installation of the
Key Reset switch.
*
*
*
Figure 23 Replacement
Figure 23a(s). Generic Machine Interface, MINI-SCREEN MSC..-1S2E Systems with the MSA-RM-1 relay pack
WARNING . . .
User must comply with all product manuals
and relevant regulations.
WARNING . . .
All MINI-SCREEN System output
contacts (FSD1, FSD2, and SSD)
must be used. The generalized wiring
configuration shown here is provided
only to illustrate the importance of proper
installation. The actual details of wiring of
the MINI-SCREEN system to any particular
machine is solely the responsibility of the
installer and end user.
WARNING . . .
Arc
Suppressors
If arc suppressors are used, they must
be installed as shown across the coils
of the safety relays. Never install arc
suppressors directly across the output
contacts of any safeguarding device.