Default Map
Main Menu > System > Communications > Industrial EtherNet > Map > Default
Automatically maps sensor data for each inspection. Recommended when execution order of sensor types is the same
across inspections. When inspection has multiple sensors, the first 5 sensor results will be shown starting at offset 55.
Each sensor result will occupy 20 words.
Table 34: PCCC PLC Input Registers (iVu Plus Outputs, N7 Table): DEFAULT MAP
WORD #
WORD NAME
Data Type
0
Input Bits ACK Register (see
Input and Output Flags
on page 144)
16-bit integer
1
Output Bits Register (see
Input and Output Flags
on page 144)
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
16
Sensor Pass/Fail Coil
16-bit integer
17-29
reserved
16-bit integer
30-52
Inspection Name
2-Word 20-Unicode chars
53-54
Frame Number
32-bit integer
55
Sensor Type ID (Sensor 1)
16-bit integer
56-74
Sensor 1 Specific Data
16-bit integer
75
Sensor Type ID (Sensor 2)
16-bit integer
76-89
Sensor 2 Specific Data
16-bit integer
95
Sensor Type ID (Sensor 3)
16-bit integer
95-114
Sensor 3 Specific Data
16-bit integer
115
Sensor Type ID (Sensor 4)
16-bit integer
116-134
Sensor 4 Specific Data
16-bit integer
135
Sensor Type ID (Sensor 5)
16-bit integer
136-154
Sensor 5 Specific Data
16-bit integer
155-170
reserved
16-bit integer
171
Command Status
16-bit integer
172
Command Response Int16
16-bit integer
173-174
Command Response Int32
32-bit integer
175-176
Command Response Float
Float
177-178
Command Response Length
32-bit integer
179-228
Command Response Data
100 Byte Array
229-239
reserved
16-bit integer
NOTE: If the inspection contains more than 5 sensors, the sensor after the 5th one will not be on the
map.
Table 35: Area Sensor Type ID = 2
Sensor Specific Data
Data Size
Area Count
32- bit integer
Area Range Min
32- bit integer
Area Range Max
32- bit integer
iVu Plus TG Gen2 Image Sensor
140