5. Within 3 seconds (before the reader flashes), position the code closest to your application code size at the center of
the Field of View (equidistant from the laser pointers). The code must not move during this procedure.
0.30 mm
Figure 45. Code Position
The Autofocus procedure ends when the Reading Distance and PPI values are successfully saved in the reader
memory, the Aim LED stops blinking and ABR 7000 emits three high pitched beeps.
If the Autofocus cannot be reached after a timeout of about 3 minutes, the ABR 7000 exits without saving the
parameters to memory, the Aim LED stops blinking, and the ABR 7000 emits a long low pitched beep.
4.4 Setup
Once entered, the imager automatically performs the Image Acquisition parameter calibration for the specific code
presented to it.
1. Enter Setup mode by pressing and holding the Smart Teach button until the Setup LED is on.
Figure 46. Smart Teach Interface: Setup Mode
2. Release the button to enter Setup mode.
The Setup LED blinks until the procedure is completed. The Setup procedure ends when the Image Acquisition
parameters are successfully saved in the reader memory, the Setup LED stops blinking, and the ABR emits three
high pitched beeps.
3. If the calibration cannot be reached after a timeout of about 5 (five) seconds, ABR exits without saving the
parameters to memory, the Setup LED stops blinking, and the ABR emits a long low pitched beep.
4.5 Learn
Once entered, the imager starts a procedure to automatically detect and recognize a single code
13
which is presented to it.
Successive Learns will substitute the current code. To configure multiple codes, use the Barcode Manager Auto-learn
procedure.
Exit Learn mode at any time by pressing the Smart Teach button once. After a short delay the Learn procedure is cancelled.
1. Enter Learn mode by pressing and holding the Smart Teach button until the Learn LED is on.
Figure 47. Smart Teach Interface: Learn Mode
2. Release the button to enter Learn mode.
The Learn LED blinks until the procedure is complete. The Learn procedure ends when the Image Processing and
Decoding parameters for a single code are successfully saved in the reader memory, the Green Spot is activated,
the Learn LED stops blinking, and the ABR emits 3 high pitched beeps.
Note: The PPI (Pixels Per Inch) Setup Chart cannot be used to set the Code 128 symbology (even though
the reader successfully reads the code). Use the application-specific code if you need to set this
symbology.
Note: If you have used this procedure to configure the ABR, go to
on page 36.
13
The Learn procedure does not recognize the following symbologies: Postal Codes, Pharmacode, MSI, Standard 2 of 5, or Matrix 2 of 5. Configure
through Barcode Manager for these codes.
ABR 7000 Series Barcode Reader
38
www.bannerengineering.com - Tel: + 1 888 373 6767