6. After the chart is positioned, click Pause to stop image acquisition.
Figure 53. Chart Positioned
7. Click Image Settings.
8. Click
Image Auto Setup to automatically acquire the best exposure time and gain values.
9. Select the reading option.
• Static reading—No maximum limit on exposure time
• Dynamic reading—Maximum allowable image exposure is automatically calculated using the parameters
Figure 54. Image Auto-Setup Window
Note: For applications having multiple lighting or code reading conditions, up to 10 different Image
Setups can be configured by adding them with the
icon.
10. Click Start.
11. Click Apply.
ABR 7000 Series Barcode Reader
44
www.bannerengineering.com - Tel: + 1 888 373 6767