Troubleshooting 53
After software update
ML Gateway not working after software update
Detecting if ML Gateway is running
The following are signs that the ML Gateway application is not running:
- The front panel indicator does not turn green approximately 1 minute after being switched on.
- Briefly pressing the setup button produces no visible feedback on the front panel indicator.
- The unit automatically reboots every minute or so (check for system boot indication on the front panel or critical error indication).
If the application seems to be running, but you cannot connect either via web or via telnet (command line interface), first check that the network is
working as usual; then try resetting the network settings through the front panel.
Click here for information about CLI command.
- Restarting ML Gateway with factory-installed software
If a software update causes ML Gateway to fail (for example due to power failure during flash update), the unit can be restarted using the original
factory-installed software.
To do this, switch ML Gateway off, and while pressing the setup button, switch it back on. Release the setup button after 5 seconds. This will start
the system using the original factory software, but will not fix or replace the ‘broken’ software. You must to log into the system and perform a
software upgrade to ‘repair’ the software.
If you suspect that the failure is inherent to the latest software installed (and not a failure during the flash process), you can manually download an
earlier software version from BeoWise to you computer, and perform a software update from that file.
- Erasing entire configuration before application start
If the application fails to start even if restarting on factory-installed software, there is a method for erasing the entire configuration from ML
Gateway before the application starts up. This may be useful in case of a corrupt configuration, or a configuration which causes the factory-
installed software to fail.
The entire configuration is erased if the setup button is pressed when the application starts (front panel indicator goes from red to green) and is
released within 1 second. The procedure for this is to power up ML Gateway with the setup button pressed, and release is as soon as the front
panel indicator goes from red to green (approximately 40 seconds after power-up).