Supported devices 43
Lutron HomeWorks QS / Radio Ra2
This driver is used to communicate with both Lutron Homewoks QS and Lutron Radio RA2 systems.
Connection to a Radio RA2 system
Communications with Radio RA2 is done via the Radio RA2 Main Repeater, which allows interaction with the system via 100 programmable virtual
buttons (‘phantom buttons’). This device provides both RS232 and Ethernet interfaces.
Connection to the RS232 interface can be done directly using a 3-wire RS232 cable and it is fixed at:
- Bits per second
9600
- Data bits
8
- Parity
none
- Stop bits
1
- Flow control
none
Connection to a Homeworks QS system
Communication with the Homeworks QS system is done via the Ethernet interface on the Homeworks QS Processor. Connection settings for
Ethernet consist of:
- IP address of the Main Repeater:
192.168.1.50 (default)
-
Login:
lutron
(default)
-
Password
integration
(default)
- Telnet IP port
23 (default)
Defining resources
On the device setup screen, you should identify all the components with which you need to interact. These include:
- Master Control units
- Keypads
- Interfaces
! Note that resources are the entire components and not the individual buttons within them. Each Radio RA2 resource has a name and an ID. The ID
field corresponds to the identification number in the Radio RA2 system and ranges from 1 to 100. Use the monitoring facilities or the Radio RA2
telnet terminal in order to obtain the component IDs.
Homeworks QS / Radio RA2 events and commands
An event corresponds to a button press, release, hold, or multi-tap on one of the device buttons. Supported commands are button presses, button
holds and button releases.