Technical data
4.1.5 Device interfaces
4.1.5.1 SDL/DVI receiver (5DLSDL.1001-00)
4.1.5.1.1 Overview
Information:
For information about SDL/DVI operation, see section
The interfaces available on the device or module are numbered for the purpose of clear differentiation.
The numbering used by the operating system may deviate, however.
The receiver interfaces are located on the back of the complete system.
(1)
(2)
(3)
(4)
(5)
(6)
(7) (8) (9)
Figure 4: Overview of interfaces - SDL/DVI receiver link module
No. Interface name
Chapter
No. Interface name
Chapter
1
Panel In SDL/DVI
6
Power 24 VDC
2
USB1
7
Grounding
3
USB2
8
Brightness (DVI) +
4
USB In
9
Brightness (DVI) -
5
COM
4.1.5.1.2 +24 VDC power supply
Danger!
The device is only permitted to be supplied with a SELV/PELV power supply unit or with safety extra-low
voltage (SELV) per EN 60950.
The necessary 3-pin connector is not included in delivery; for suitable accessories, see
The device is protected against overload and reverse polarity by a soldered fuse (10 A, fast-acting). If the fuse
is defective (e.g. due to overload), the device must be sent to B&R for repairs. If the polarity is reversed, it is not
necessary to replace the fuse.
Pin
Description
Figure
1
-
2
Functional ground
3
+
•
Reverse polarity protection
•
3-pin
•
Male
1 2 3
Electrical properties
Nominal voltage
24 VDC ±25%, SELV
1)
Nominal current
Max. 3 A
Overvoltage category per EN 61131-2
II
Galvanic isolation
Yes
Uninterruptible power supply
No
1)
EN 60950 requirements must be observed.
Automation Panel 1000 - Hygienic design user's manual V2.00