CHAPTER 9
Updating, Maintenance and Troubleshooting
87
Fig.9.6
Restore factory firmware
and settings on hardware
version 4
c) Press the
Accept
pushbutton
to restore factory firmware and settings.
2) (all hardware versions) If the instrument now functions normally, define your preferred
settings in the
Preferences
menu, adjust the touch screen again and make necessary
changes to
Setup
(all accessed via the Main Menu
).
If you experience problems selecting another template or you login as another user, then note
which step causes the problem. You might need to delete/reconfigure the templates or users.
To delete/reconfigure templates or users, use Measurement Partner Suite BZ-5503 with the
analyzer connected to the PC via Micro USB Cable AO-1494 (G4 hardware) or Mini USB
Cable AO-1476, or a modem/LAN connection. Please consult the on-line help included with
the BZ-5503 software for instructions on how to configure the analyzer.
Re-installing Software (Hardware Versions 1 – 3)
If the instrument still does not work normally after performing the ‘Reset to Default Settings’
procedure, then the software might need to be re-installed. This can be done in two ways:
1) If the connection to Measurement Partner Suite BZ-5503 works with the instrument
connected to the PC using a USB cable, then the software can be re-installed and re-
configured through the USB cable. Please consult the on-line help included with the
BZ-5503 software for instructions on how to re-install software on 2250 Light.
2) If the connection to the PC does not work, then you need a Compact Flash card (size at
least 64 Mbytes) and a Compact Flash card reader for the PC. You can then use
Measurement Partner Suite BZ-5503 to update the Compact Flash card with the necessary
files. Please consult the on-line help included with the BZ-5503 software for instructions
on how to update a Compact Flash card with installation files for 2250 Light.
Power off 2250 Light and insert the compact flash card in the CF slot on the instrument.
Then press and hold down the
Manual Event 2
and
Save
pushbuttons while
switching on the instrument. The Maintenance Mode initial screen will be displayed, and
then within a few seconds the screen shown in Fig.9.4 will appear.
Содержание 2250 Light
Страница 2: ......
Страница 10: ......
Страница 48: ...38 2250 Light User Manual...
Страница 58: ...48 2250 Light User Manual...
Страница 116: ...106 2250 Light User Manual...
Страница 126: ...116 2250 Light User Manual...
Страница 136: ...126 2250 Light User Manual...
Страница 168: ...2250 Light User Manual 158...
Страница 205: ......
Страница 206: ......
Страница 207: ......