BR24
34
UK
BR24 / AS05560
Electronic control unit
for the automation of a 24 Vdc barrier
230Vac monophase 50/60 Hz
1
24 Vdc
24Vdc 10W max
230Vac 3W max
24Vdc - 230Vac free relay contact
24Vdc - 230Vac free relay contact
24Vdc 3W max
24Vdc 8W max including accessories power supply
Plug-in
-20°C +60°C
24Vdc 8W max including safety devices power supply
Control unit
Type
Power supply
No. Motors
Motor power supply
Flashing light
Boom lights
Courtesy light
Electromagnet / Electric lock
Warning light
Safety devices power supply
Radio receiver
Operating temperature
Accessories power supply
TECHNICAL SPECIFICATIONS / FUNCTIONS
• Red leds of NC contacts. There is not the safety devices led. See “SIGNALLING LEDS” table.
• Green / yellow leds of NO contacts. See “SIGNALLING LEDS” table.
• Management of 2 control units synchronized between them
• Management of 1 electric lock or electromagnet.
• Management of courtesy light.
• Management of 230 Vac boom lights
• Management of traffic light.
• Enabling the photocell test done before the opening and closing movement.
• Enabling the test of the amperometric circuit and conductive edge 8k2 done before the opening and closing
movement.
• Stop and motion inversion for 1 s after safety devices intervention . At the next START pulse, the motion
restarts in the obstacle freeing direction.
• Separate safety devices power supply. Connect to this terminals the safety devices that will be tested.
• Double reading of the limit switch always active, except in dead man operating logic.
• Decelerations always active except in dead man operating logic.
• Working time in opening and closing fixed at 10 sec.
• Deceleration time in opening and closing fixed at 10 sec.
• Motor power fixed at 10 level.
• Digital programming of all functions.
• Adjustable pause time.
• Deceleration speed that can be selected between adjustable mode on 10 levels (with terminal block JP13
open) or fixed mode by secondary transformer (green or red cable on faston CF1)
• Control of current absorption (anti-crushing) adjustable on 100 levels both in thrust phase and in deceleration
phase.
• 4 operating logics: step by step with stop, step by step, condominium or automatic, dead man.