• Anti-crushing enabling only in closing (motion inversion for 1 second and locking) or amperometric detection for
limit switch active both in opening and closing.
• Programming of: automatic closing, fast closing, preflashing, fixed or intermittent flashing light, management of
an external clock with 3 different modes, cycles number for planned maintenance, installer code, number of
cycles done, number of powered days.
INSTALLATION WARNINGS
• Before proceeding with the installation, fit a magneto-thermal or differential switch with a maximum capacity of
10A upstream of the system. The switch must guarantee omnipolar separation of the contacts, with an opening
distance of at least 3 mm.
• To prevent possible interferences, differentiate and always keep the power cables (minimum cross-section
1,5mm²) separate from the signal cables (minimum cross-section 0,5mm²).
• Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that must be connected to the same N.C. (normally closed) input and in
parallel all the devices that share the same N.O. (normally open) input. Incorrect installation or improper use of
the product may compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device, if the original
components and accessories suitable for the specific automation are not used.
• At the end of the installation, always check carefully the proper functioning of the system and devices used.
• This instruction manual addresses people qualified for the installation of “live equipment”. Therefore good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carry out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed. Check the aim of the final use
and be sure to take all the necessary safeties.
• Use of the products for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
• Mark the automated gate with visible warning plates.
• Warn the user that children and animals may not play or stand around near the gate.
• Appropriately protect the dangerous points (for example, use a conductive edge).
• The control unit does not assure by it self the safety against crushing. Be sure that the safety devices
connected to the control unit are fit for purpose.
WARNINGS FOR THE USER
In the event of an operating fault or failure, cut the power upstream of the control unit and call the Technical
Service.
Periodically check the functioning of the safety devices. Any repairs must be carry out by specialised personnel
using original and certified materials.
The appliance is not to be used by children or people with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction.
Do not touch the card for adjustments and/or maintenance.
WARNING: IMPORTANT SAFETY INSTRUCTIONS
It is very important to follow the present instructions for your own safety.
Please keep this manual.