TRAFFIC LIGHT OPERATION
WARNING: in the drawings n. 5 and 6 the power for the lights must be taken outside the control board. If
not possible please refer to the electrical features of the control board, being careful not to overload the
output power accessory.
ONE WAY TRAFFIC LIGHT
Operation
:
the red light will be always on until the complete opening of the barrier. It will switch off at the beginning of the
pause time and at the same time the green led will switch on. At start closing the green light will switch off and
the red one will switch on.
With dead man logic the green light will switch on at the interception of the opening limit switch. As soon as the
closing begins the green light will switch off and the red one will switch on.
WARNING
: with this settings the terminal block JP5 will no more be available for connecting a courtesy light
while the terminal block JP4 will remain available for connecting an electric lock or an electromagnet
TWO WAY TRAFFIC LIGHT WITH RESERVATION
WARNING
: It is recommended the AUTOMATIC /CONDOMINIUM logic
Operation
:
The START command and the channel n. 1 of a stored transmitter will active the system and reserve the input
traffic light. The button “+” on the control board will open but it will not active the traffic light.
The red light will be always on until the complete opening of the barrier. It will switch off at the beginning of the
pause time and at the same time the green led will switch on. At start closing the green light will switch off and
the red one will switch on.
The OPEN command and the channel n. 2 of a stored transmitter will active the system and reserve the output
traffic light. (Note that OPEN command and channel 2 of the transmitter are now working as START).
The red light will be always on until the complete opening of the barrier. It will switch off at the beginning of the
pause time and at the same time the green led will switch on. At start closing the green light will switch off and
the red one will switch on.
The traffic light reservation will be cancelled at the end of closing phase, so a command during pause or during
closing will not change the reservation previously activated.
With dead man logic it is not possible to use the two way traffic light with reservation
WARNING
: with this settings the terminal blocks JP4 and JP5 will no more be available for connecting a
courtesy light or an electric lock or an electromagnet