BR24
43
UK
STEP - STEP
LOGIC
A3
A3
A3
AUTOMATIC /
CONDOMINUM
LOGIC
DEAD MAN
LOGIC
3
4
5
Command OPEN
- With gate closed it opens but does not make the automatic closing
- During opening is irrelevant
- During pause is irrelevant
- During closing inverts the motion toward opening and it will not follow
an automatic closing.
WARNING
: the OPEN command changes its function if you use a traffic
light and select the menu E20-3.
Refer to the paragraph related to the traffic light operation
Command CLOSE
- During opening inverts the motion toward closing
- During pause enables closing
- During closing is irrelevant
- With gate closed is irrelevant
It enables the AUTOMATIC/CONDOMINIUM logic
Operation
:
Command START
START
→
open
Next START(S)
→
irrelevant if the system is opening, or it reset the
pause time (if the gate is in pause and the automatic closing is
activated).
When the pause time has elapsed:
If the automatic closing is activated, the system closes automatically.
If the automatic closing is not activated, a START command close the
gate.
In closing a START command opens.
Command OPEN
- With gate closed it opens but does not make the automatic closing
- With gate closed it opens but does not make the automatic closing
- During opening is irrelevant
- During pause is irrelevant
- During closing inverts the motion toward opening and it will not follow
an automatic closing.
WARNING
: the OPEN command changes its function if you use a traffic
light and select the menu E20-3.
Refer to the paragraph related to the traffic light operation
Command CLOSE
- During opening inverts the motion toward closing
- During pause enables closing
- Durino closing is irrelevant
- With gate closed is irrelevant
It enables the DEAD MAN logic
Operation
:
OPEN
button
→
opens only if the button is held down.
CLOSE
button
→
closes only if the button is held down.
START command is irrelevant.
With Dead Man Logic the (START) and OK (STOP) on the
control board are irrelevant.
With the movement the electromagnet and the courtesy light will turn on.
With dead man logic the opening and closing movement will stop
always on the first limit switch.