System Troubleshooting

Regulator Troubleshooting 

The majority of charging difficulties can be attributed to damage, corrosion or wear at wiring, fusing or wiring connections. 

Before attempting to troubleshoot alternator or regulator issues, be sure to address the following:

1. 

Remove and clean all charging system electrical connections (positive and negative). Check the voltage regulator’s 

harness for continuity. Wires and terminals can and will become corroded, and need to be cleaned or replaced. Ensure 

that the regulator’s ground wires are provided with a clean connection to system ground.

2. 

Inspect and replace 10A and 1A ATC type fuses in the regulator wiring harness if fuse appear to be damaged or 

corroded. Ensure that the fuse holder is also free of corrosion.

3. 

Charge all batteries to their proper fully charged state, and determine if they are serviceable. If your batteries are 

flooded-type, use your hydrometer to determine their condition.

4. 

Check and tighten alternator belt. If the belt show signs of wear or damage, replace it. Always replace existing belts with 

the finest quality replacements available.

If batteries and wiring are in suitable condition, use the following tests to determine if charging problems are a result of a faulty 

alternator or regulator. These tests provide an opportunity to isolate the alternator, regulator and wiring harness in order to 

determine the problem source. In order to perform these tests, you will need an independent DC meter (preferably a digital 

type). In an emergency, a 12V light bulb or test light can be used to help determine if power or working grounds exist. An amp 

meter and a battery hydrometer with a thermometer are also helpful diagnostic tools.

Voltage Regulator Testing

Set your voltmeter to 12VDC and connect the negative lead to the BLACK ground wire at the regulator as shown at the diagram 

at right.

1.  With the ignition turned OFF, check voltage on the RED (power), Voltage Sense (Terminal #9), BLUE (field) and 

BROWN (Ignition) wires in the regulator plug.

Voltages should be as follow:

• 

RED wire equal to battery voltage

• 

Terminal #9 RED wire equal to battery voltage

• 

BLUE wire zero volts

• 

BROWN wire zero volts

2.  With the ignition in the ON position (engine not running), 

check voltage on the RED (power), Secondary RED on 

Terminal #9 (voltage sense) BLUE (field) and BROWN 

(ignition) wires in the regulator plug:

• 

RED wire equal to battery voltage

• 

Terminal #9 RED wire equal to battery voltage

• 

BLUE wire between 4V and 11V

• 

BROWN wire equal to battery voltage

PLEASE NOTE: In systems where the ignition (BROWN) wire is supplied power via an oil pressure switch, jump directly 

from test #1 to test #3.
3.  With the ignition in the ON position (with engine running at 1,400 rpm fast idle), check voltage on the RED (power), 

Secondary RED on Terminal #9 (voltage sense) BLUE (field) and BROWN (ignition) wires in the regulator plug. Voltages 

should be as follows:

• 

RED wire equal to battery voltage

• 

Terminal #9 RED wire equal to battery voltage

• 

BLUE wire between 4V and 11V

• 

BROWN wire equal to battery voltage

If voltage is not present on the RED, the BROWN and the Positive Battery Sense Wire, the regulator will not work. If voltage is 

as expected at the RED the BROWN and Positive Battery Sense wire, and there is zero, or an unexpected voltage reading at 

the BLUE wire, contact our technical support staff at +1(360) 435-6100, or e-mail us at [email protected].
If all voltages at the regulator meet expectations, yet the alternator is not producing charging current, test the alternator. The 

following tests are recommended for determining alternator functionality.

Содержание MAX CHARGE MC-614

Страница 1: ...thing or jewelry which could become entangled in your motor or other machinery prior to installing regulator 3 Wear ANSI approved safety eye wear and protective gear 4 DO NOT attempt to modify the reg...

Страница 2: ...tors distance from alternator distance from inverters transmitters and other sources of RF noise convenient access and readability of the display The regulator wiring harness is 54 inches long providi...

Страница 3: ...E 10 DATA TX 11 DATA RX 12 STATOR IN 13 TACHOMETER OUT 14 BAT 2 TEMP 15 BAT 2 TEMP 16 AUX 1 LAMP 17 DASH LAMP MC 614 Regulator Terminal Layout Magnetic Reed Switch 17 16 15 14 13 12 11 10 9 8 7 6 5 1...

Страница 4: ...ug or a ring terminal depending on the alternator s field terminal connection Attach the field wire to the alternator s field terminal Install Alternator Temperature Sensor The optional Alternator Tem...

Страница 5: ...e alternator stator output it will be necessary to determine the number of poles in the alternator in order to properly adjust your tachometer Most Balmar alternators feature 12 pole rotors and stator...

Страница 6: ...gulator s programming tool A small magnet embedded in the top of the screwdriver s handle allows the user to activate the magnetic reed switch By holding the magnet to the RED dot located at the end o...

Страница 7: ...ltage for a set time period specified by the battery program selected Factory set values are 13 9 volts for 0 3 hours 18 minutes and are adjustable with Av and A1c respectively See page 14 7 Calculate...

Страница 8: ...Flooded Halogen Systems Lithium Yes Yes Yes Yes Yes Balmar Alternator Models 6 Series Alternators 70A 150A Yes Yes Yes Yes Yes Yes AT Series Alternator 165A 200A Yes Yes Yes Yes 9 Series Large Case A...

Страница 9: ...ER 55 C FACTORY DEFAULT E21 BATTERY 2 TOO HOT OVER 55 C FACTORY DEFAULT E22 ALTERNATOR TOO HOT OVER 107 C E24 VOLTAGE REGULATOR TOO HOT OVER 90 C E33 BATTERY SENSE DIS CONECTED E41 FIELD VOLTAGE TOO H...

Страница 10: ...he reed switch Within the basic and advanced programming instructions activation of the reed switch will be described by the following actions TOUCH RELEASE Indicates the action of contacting and imme...

Страница 11: ...cifics Your battery manufacturer may supply you with a C rate for charging and discharging The maximum amount of charging current your battery can safely handle is determined by multiplying the C Rate...

Страница 12: ...ax b 2 90 Field Max b 3 85 Field Max b 4 80 Field Max b 5 75 Field Max b 6 70 Field Max b 7 65 Field Max b 8 60 Field Max b 9 55 Field Max AL2 2nd Alternator Sensor Mode b2 2nd Battery Sensor Mode Sd...

Страница 13: ...0 INDICATES BLM OFF b 1 INDICATES BLM SETTING 1 FIELD REDUCTION 5 b 2 INDICATES BLM SETTING 2 FIELD REDUCTION 10 b 3 INDICATES BLM SETTING 3 FIELD REDUCTION 15 b 4 INDICATES BLM SETTING 4 FIELD REDUC...

Страница 14: ...croll upward or downward To reverse the direction of scroll 1 REMOVE the magnet from the reed switch 2 Wait for the mode indicator to be displayed 3 TOUCH HOLD when the mode indicator is displayed The...

Страница 15: ...it Allows user control of regulator s low voltage limit Spans between 10 volts and Fv Dropping below ALL causes Dash Lamp to turn on Default is 12 7 volts in 1 volt increments FbA Field Threshold Bulk...

Страница 16: ...on Low Battery Voltage 12 8V Adjustable with ALL See Page 12 High Battery Voltage 15 5V Adjustable with AHL See Page 11 High Alternator Temperature 225 F Adjustable with AL1 See Page 12 Requires insta...

Страница 17: ...An amp meter and a battery hydrometer with a thermometer are also helpful diagnostic tools Voltage Regulator Testing Set your voltmeter to 12VDC and connect the negative lead to the BLACK ground wire...

Страница 18: ...t test Testing the actual output of the alternator is known as Full Field Testing This can be accomplished by jumping a positive 12VDC current to the field terminal at the rear of the alternator This...

Страница 19: ...plication maintenance or modification or b any misuse contrary to the instructions provided with the product or c loss or d malfunctions caused by other equipment or e acts of God Examples of conditio...

Страница 20: ...he world To Find a CDI distribution partner visit www cdielectronics com Both Balmar and CDI Products are manufactured in our ISO 9000 Certified Factory in Huntsville Alabama Please read carefully All...

Отзывы: