Programming The Belt Load Manager

The MC-614 provides the ability to manage regulator field potential, making it possible to govern the horsepower loads placed 

on the drive belt(s) by the alternator. The Belt Load Manager can also be used to protect the alternator from extraordinary 

load created by a battery load that’s too large for the alternator’s capacity. The Belt Load Manager is accessed in the basic 

programming mode, directly after the battery type programming mode. The Belt Load Manager can be accessed at the same 

time the battery program is set, or by itself. 
When activating the programming mode, keep in mind that the regulator will scroll through the basic programming mode three 

times before saving and returning to the operational mode. To adjust the regulator for your battery type:

1. 

Turn on the regulator. If the regulator’s BROWN ignition wire is connected to an oil pressure switch, it may be necessary to 

start the engine to activate the regulator.

2. 

If the battery type program has been adjusted, TOUCH/HOLD when entry into the Belt Load Manager is indicated by the 

bEL display on the regulator’s LED.

3. 

If you don’t wish to adjust the battery programming, TOUCH/HOLD the RED dot when the regulator is activated. RELEASE 

when the Pro display is indicated. The regulator will indicate bA, for battery type, and will cycle to bEL.

4. 

TOUCH/HOLD. The regulator display will indicate b-0 (indicating that the Belt Load Manager is off). Continue to HOLD 

the regulator display to scroll through seven settings. Each setting decreases the field potential by approximately seven 

percent.

5. 

RELEASE when the display indicates your desired level of field reduction. The display will cycle to bEL. You can re-activate 

to change your selection, or wait until the regulator cycles to the next programming mode.

6. 

If no other changes are made to the Belt Load Manager program, the regulator will cycle to the next programming mode.

bEL

 INDICATES ENTRY INTO 

BELT LOAD MANAGER MODE

b-0

 INDICATES BLM OFF.

b-1

 INDICATES BLM SETTING #1. 

FIELD REDUCTION 5%.

b-2

 INDICATES BLM SETTING #2. 

FIELD REDUCTION 10%.

b-3

 INDICATES BLM SETTING #3. 

FIELD REDUCTION 15%.

b-4

 INDICATES BLM SETTING #4. 

FIELD REDUCTION 20%.

b-5 

INDICATES BLM SETTING #5. 

FIELD REDUCTION 25%.

b-6

 INDICATES BLM SETTING #6. 

FIELD REDUCTION 30%

b-7

 INDICATES BLM SETTING #7. 

FIELD REDUCTION 35%.

b-8

 INDICATES BLM SETTING #8. 

FIELD REDUCTION 40%

b-9

 INDICATES BLM SETTING #9.

FIELD REDUCTION 45%

Programming For Short or Long Display Mode

You can choose the amount of information displayed on the regulator. The information displayed on the short or long display is 

detailed on Page 8

 

of the manual. To adjust the regulator for short or long display:

1. 

TOUCH/HOLD when entry into the short/long display selector is indicated by dSP on the regulator’s LED.

2. 

The regulator display will indicate codes Sd (for short display) or Ld (for long display).

3. 

RELEASE when the display indicates your desired display mode. The display will cycle to dSP. You can re-activate to 

change your selection, or wait until the regulator cycles to the next programming mode.

dSP

 INDICATES ENTRY INTO SHORT 

OR LONG DISPLAY MODE

Sd 

INDICATES SHORT 

DISPLAY MODE

Ld

 INDICATES LONG 

DISPLAY MODE

Programming For Alternator Failure Advisory Mode (BDL)

The regulator provides a ground signal on the dash lamp terminal when the following conditions occur: low battery voltage 

(<12.7V), high battery voltage (>15.5V), high battery temperature (<52°C), or high alternator temperature (105°C). In 

addition, the user has the option to send the dash lamp ground in the event that the stator output drops to zero volts. The 

Regulator’s Default bdL setting is ON. Monitoring stator output is an optional function which can be turned on or off in the basic 

programming mode. The regulator’s default setting for the bdL mode is ON, meaning that the stator output is being monitored. 

This function can be used in conjunction with a relay to control a charge indicator lamp.

1. 

To enable or disable the stator monitoring function, activate and hold when the bdL mode is indicated.

2. 

Release when the desired setting is shown. NOTE: Stator wire must be connected to the regulator’s Stator-In terminal to 

use this function.

bdL

 INDICATES ENTRY INTO 

ALTERNATOR FAILURE 

ADVISORY MODE

OFF

 STATOR OUTPUT 

MONITORING OFF

ON

 STATOR OUTPUT 

MONITORING ON

Содержание MAX CHARGE MC-614

Страница 1: ...thing or jewelry which could become entangled in your motor or other machinery prior to installing regulator 3 Wear ANSI approved safety eye wear and protective gear 4 DO NOT attempt to modify the reg...

Страница 2: ...tors distance from alternator distance from inverters transmitters and other sources of RF noise convenient access and readability of the display The regulator wiring harness is 54 inches long providi...

Страница 3: ...E 10 DATA TX 11 DATA RX 12 STATOR IN 13 TACHOMETER OUT 14 BAT 2 TEMP 15 BAT 2 TEMP 16 AUX 1 LAMP 17 DASH LAMP MC 614 Regulator Terminal Layout Magnetic Reed Switch 17 16 15 14 13 12 11 10 9 8 7 6 5 1...

Страница 4: ...ug or a ring terminal depending on the alternator s field terminal connection Attach the field wire to the alternator s field terminal Install Alternator Temperature Sensor The optional Alternator Tem...

Страница 5: ...e alternator stator output it will be necessary to determine the number of poles in the alternator in order to properly adjust your tachometer Most Balmar alternators feature 12 pole rotors and stator...

Страница 6: ...gulator s programming tool A small magnet embedded in the top of the screwdriver s handle allows the user to activate the magnetic reed switch By holding the magnet to the RED dot located at the end o...

Страница 7: ...ltage for a set time period specified by the battery program selected Factory set values are 13 9 volts for 0 3 hours 18 minutes and are adjustable with Av and A1c respectively See page 14 7 Calculate...

Страница 8: ...Flooded Halogen Systems Lithium Yes Yes Yes Yes Yes Balmar Alternator Models 6 Series Alternators 70A 150A Yes Yes Yes Yes Yes Yes AT Series Alternator 165A 200A Yes Yes Yes Yes 9 Series Large Case A...

Страница 9: ...ER 55 C FACTORY DEFAULT E21 BATTERY 2 TOO HOT OVER 55 C FACTORY DEFAULT E22 ALTERNATOR TOO HOT OVER 107 C E24 VOLTAGE REGULATOR TOO HOT OVER 90 C E33 BATTERY SENSE DIS CONECTED E41 FIELD VOLTAGE TOO H...

Страница 10: ...he reed switch Within the basic and advanced programming instructions activation of the reed switch will be described by the following actions TOUCH RELEASE Indicates the action of contacting and imme...

Страница 11: ...cifics Your battery manufacturer may supply you with a C rate for charging and discharging The maximum amount of charging current your battery can safely handle is determined by multiplying the C Rate...

Страница 12: ...ax b 2 90 Field Max b 3 85 Field Max b 4 80 Field Max b 5 75 Field Max b 6 70 Field Max b 7 65 Field Max b 8 60 Field Max b 9 55 Field Max AL2 2nd Alternator Sensor Mode b2 2nd Battery Sensor Mode Sd...

Страница 13: ...0 INDICATES BLM OFF b 1 INDICATES BLM SETTING 1 FIELD REDUCTION 5 b 2 INDICATES BLM SETTING 2 FIELD REDUCTION 10 b 3 INDICATES BLM SETTING 3 FIELD REDUCTION 15 b 4 INDICATES BLM SETTING 4 FIELD REDUC...

Страница 14: ...croll upward or downward To reverse the direction of scroll 1 REMOVE the magnet from the reed switch 2 Wait for the mode indicator to be displayed 3 TOUCH HOLD when the mode indicator is displayed The...

Страница 15: ...it Allows user control of regulator s low voltage limit Spans between 10 volts and Fv Dropping below ALL causes Dash Lamp to turn on Default is 12 7 volts in 1 volt increments FbA Field Threshold Bulk...

Страница 16: ...on Low Battery Voltage 12 8V Adjustable with ALL See Page 12 High Battery Voltage 15 5V Adjustable with AHL See Page 11 High Alternator Temperature 225 F Adjustable with AL1 See Page 12 Requires insta...

Страница 17: ...An amp meter and a battery hydrometer with a thermometer are also helpful diagnostic tools Voltage Regulator Testing Set your voltmeter to 12VDC and connect the negative lead to the BLACK ground wire...

Страница 18: ...t test Testing the actual output of the alternator is known as Full Field Testing This can be accomplished by jumping a positive 12VDC current to the field terminal at the rear of the alternator This...

Страница 19: ...plication maintenance or modification or b any misuse contrary to the instructions provided with the product or c loss or d malfunctions caused by other equipment or e acts of God Examples of conditio...

Страница 20: ...he world To Find a CDI distribution partner visit www cdielectronics com Both Balmar and CDI Products are manufactured in our ISO 9000 Certified Factory in Huntsville Alabama Please read carefully All...

Отзывы: