 Recommendations

Our LFP program is a generalized version of the recommendations provided by the top LFP battery manufacturers. 

For best performance and compatibility, please consult your battery manufacturer and use the regulator’s advanced 

programming features to adjust the LFP program as needed. LFP batteries are more sensitive to abuse than a 

traditional chemistry battery and can fail catastrophically. It is HIGHLY recommended that the charging system as 

a whole be installed or inspected by a qualified marine electrical installer that has experience with Balmar charging 

system products and LFP batteries. The LFP profile is intended to work with the battery manufacturer’s battery 

management systems (BMS). The LFP profile IS NOT a replacement for a BMS.

Many LiFePO

4

 batteries have a Battery Management System (BMS) that may disconnect the battery 

from the alternator as a protective action or when charging is complete. The regulator must be shut down 

before the battery is disconnected .Running an alternator without a battery will damage the alternator 

and may damage any attached system. This is doubly true if the battery can be disconnected during 

high current charging, causing a load dump. The load dump can easily cause a high voltage spike 

which will destroy the alternator’s rectifier, at minimum. This is not a warrantable failure. To reiterate: 

THE ALTERNATOR MUST BE SHUT DOWN BEFORE DISCONNECTING THE BATTERY. THE ONLY 

SAFE WAY TO SHUT DOWN THE ALTERNATOR IS TO TURN OFF THE REGULATOR. The preferred 

method of turning off the regulator is disconnecting the regulator’s ignition (brown) wire, but if used as 

an EMERGENCY ONLY shutdown, disconnecting the regulator’s power input (red) wire in addition to the 

ignition wire has a very low chance of damaging the regulator.

LFP batteries will readily accept a damaging amount of current. Applying too much charge current 

to a LFP battery will, at the very least, permanently damage the battery’s capacity. It is CRITICAL to 

ensure that the alternator is not capable of exceeding the maximum continuous charge current rating of 

your battery (or batteries). As always, check with your battery manufacturer for specifics. Your battery 

manufacturer may supply you with a “C-rate” for charging and discharging. The maximum amount 

of charging current your battery can safely handle is determined by multiplying the “C-Rate” by the 

capacity of the bank. i.e. 4x 100Ah 12V batteries rated at 0.5C charge = 400 Ah * 0.5C = 200amps MAX. 

If your alternator is capable of outputting more current, at any time or condition, than the battery (or 

batteries) can handle, you may use the Belt Manager feature on the MC-614 to lower the maximum field 

drive output, and thereby lower the maximum alternator output current. See page 10 of your regulator 

manual for details and instructions. Be aware that it is not an exact 1:1 correlation between field output 

and alternator output, so start with more reduction (lower output) than you think you need and adjust 

accordingly.

It is strongly recommended that an alternator temperature sensor (MC-TS-A) be used when charging LFP 

batteries. Given the extremely high charge acceptance rate of LFP batteries, the alternator will be driven 

to full output for almost all of the charge cycle. This can cause overheating in automotive style alternators 

resulting in a significantly shortened lifespan. When equipped with the MC-TS-A temperature sensor, 

the MC-614 will help you protect your investment by performing active alternator temperature control. 

This is accomplished by scaling back the field voltage to the alternator when over the “AL1” temperature 

threshold. If you cannot use an MC-TS-A in your application, you should monitor the alternator’s 

temperature (measure as close to the loop ends of the stator as possible) and discontinue charging if the 

alternator temperature rises above the maximum recommended level. You may also use the Belt Manager 

feature on your MC-614 to reduce maximum output until a tolerable alternator temperature is maintained 

under all conditions.

Most LFP battery manufacturers specify minimum and maximum charging temperatures to be from 

freezing (32°F, 0°C) to around 111°F (44°C). Again, consult with your battery manufacturer for specifics. 

When equipped with a  MC-TS-B, the MC-614 can disable charging if the battery temperature exceeds 

the “B1L” temperature threshold and re-enable charging when the temperature drops below the threshold. 

This feature is meant to supplement, not replace, your BMS’s temperature protection features. “B1L” 

should be adjusted to be slightly less than BMS’s temperature threshold. Note that the regulator does not 

have the capability to prevent charging during low temperatures.

Содержание MAX CHARGE MC-614

Страница 1: ...thing or jewelry which could become entangled in your motor or other machinery prior to installing regulator 3 Wear ANSI approved safety eye wear and protective gear 4 DO NOT attempt to modify the reg...

Страница 2: ...tors distance from alternator distance from inverters transmitters and other sources of RF noise convenient access and readability of the display The regulator wiring harness is 54 inches long providi...

Страница 3: ...E 10 DATA TX 11 DATA RX 12 STATOR IN 13 TACHOMETER OUT 14 BAT 2 TEMP 15 BAT 2 TEMP 16 AUX 1 LAMP 17 DASH LAMP MC 614 Regulator Terminal Layout Magnetic Reed Switch 17 16 15 14 13 12 11 10 9 8 7 6 5 1...

Страница 4: ...ug or a ring terminal depending on the alternator s field terminal connection Attach the field wire to the alternator s field terminal Install Alternator Temperature Sensor The optional Alternator Tem...

Страница 5: ...e alternator stator output it will be necessary to determine the number of poles in the alternator in order to properly adjust your tachometer Most Balmar alternators feature 12 pole rotors and stator...

Страница 6: ...gulator s programming tool A small magnet embedded in the top of the screwdriver s handle allows the user to activate the magnetic reed switch By holding the magnet to the RED dot located at the end o...

Страница 7: ...ltage for a set time period specified by the battery program selected Factory set values are 13 9 volts for 0 3 hours 18 minutes and are adjustable with Av and A1c respectively See page 14 7 Calculate...

Страница 8: ...Flooded Halogen Systems Lithium Yes Yes Yes Yes Yes Balmar Alternator Models 6 Series Alternators 70A 150A Yes Yes Yes Yes Yes Yes AT Series Alternator 165A 200A Yes Yes Yes Yes 9 Series Large Case A...

Страница 9: ...ER 55 C FACTORY DEFAULT E21 BATTERY 2 TOO HOT OVER 55 C FACTORY DEFAULT E22 ALTERNATOR TOO HOT OVER 107 C E24 VOLTAGE REGULATOR TOO HOT OVER 90 C E33 BATTERY SENSE DIS CONECTED E41 FIELD VOLTAGE TOO H...

Страница 10: ...he reed switch Within the basic and advanced programming instructions activation of the reed switch will be described by the following actions TOUCH RELEASE Indicates the action of contacting and imme...

Страница 11: ...cifics Your battery manufacturer may supply you with a C rate for charging and discharging The maximum amount of charging current your battery can safely handle is determined by multiplying the C Rate...

Страница 12: ...ax b 2 90 Field Max b 3 85 Field Max b 4 80 Field Max b 5 75 Field Max b 6 70 Field Max b 7 65 Field Max b 8 60 Field Max b 9 55 Field Max AL2 2nd Alternator Sensor Mode b2 2nd Battery Sensor Mode Sd...

Страница 13: ...0 INDICATES BLM OFF b 1 INDICATES BLM SETTING 1 FIELD REDUCTION 5 b 2 INDICATES BLM SETTING 2 FIELD REDUCTION 10 b 3 INDICATES BLM SETTING 3 FIELD REDUCTION 15 b 4 INDICATES BLM SETTING 4 FIELD REDUC...

Страница 14: ...croll upward or downward To reverse the direction of scroll 1 REMOVE the magnet from the reed switch 2 Wait for the mode indicator to be displayed 3 TOUCH HOLD when the mode indicator is displayed The...

Страница 15: ...it Allows user control of regulator s low voltage limit Spans between 10 volts and Fv Dropping below ALL causes Dash Lamp to turn on Default is 12 7 volts in 1 volt increments FbA Field Threshold Bulk...

Страница 16: ...on Low Battery Voltage 12 8V Adjustable with ALL See Page 12 High Battery Voltage 15 5V Adjustable with AHL See Page 11 High Alternator Temperature 225 F Adjustable with AL1 See Page 12 Requires insta...

Страница 17: ...An amp meter and a battery hydrometer with a thermometer are also helpful diagnostic tools Voltage Regulator Testing Set your voltmeter to 12VDC and connect the negative lead to the BLACK ground wire...

Страница 18: ...t test Testing the actual output of the alternator is known as Full Field Testing This can be accomplished by jumping a positive 12VDC current to the field terminal at the rear of the alternator This...

Страница 19: ...plication maintenance or modification or b any misuse contrary to the instructions provided with the product or c loss or d malfunctions caused by other equipment or e acts of God Examples of conditio...

Страница 20: ...he world To Find a CDI distribution partner visit www cdielectronics com Both Balmar and CDI Products are manufactured in our ISO 9000 Certified Factory in Huntsville Alabama Please read carefully All...

Отзывы: