Measurement error
±10 %
1)
The vibration velocity range is frequency-dependent. The specified value is the theoretical maximum within this
frequency range at an acceleration of 16 g 16 g.
Mathematics/Algorithm
The example shows a typical application of vibration monitoring.
Application example (with
vibration frequency spectrum) as
input
Total result of the
measurement as output
Description
Vibration level v-RMS
[mm/s]
2.3
4.5
7.1
A classic application is the detection of
the wear of a bearing.
The spectrum and the amplitude of the
vibration change.
A more complex mechanical system
(such as a production line) returns
more complex measurement results
(spectrum).
The output value is a total value for
simple handling.
The objective of this function is the detection of larger vibration deviations that arise between normal and
abnormal operation as well as the detection of trends (change of the values over time).
The accuracy of the measurement is limited by the application, because the
BVS ID
is mounted to perform the
primary function (e.g., optical distance measurement) and not as a sensor for vibration measurement. Thus, not
only are the vibrations of the vibration source that is to be measured, but also the vibrations of the entire
mechanical system.
This function is based on the ISO-10816-3 standard, but for a detailed vibration analysis Balluff offers special
sensors.
The product family is designed such that it offers complete monitoring functionality, whereby the status
monitoring is the primary function of the sensor and it is mounted on the object or on the machine.
Содержание BVS ID-M1280-F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Страница 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Страница 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Страница 106: ...BVS ID M1280xF1 xx xxx 104 deutsch Ablaufdiagramm eine Beispielinspektion mit Kamera Funktionsbaustein BVS_ID...
Страница 107: ...BVS ID M1280xF1 xx xxx deutsch 105 Ablaufdiagramm Inspektionsumschaltung mit Kamera Funktionsbaustein BVS_ID...
Страница 173: ...956115_AA DE K22 nderungen vorbehalten...
Страница 174: ......
Страница 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 176: ...www balluff com...
Страница 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Страница 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Страница 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...
Страница 273: ...BVS ID M1280xF1 xx xxx english 99 Flow chart of a sample inspection with camera function module BVS_ID...
Страница 274: ...BVS ID M1280xF1 xx xxx 100 english Flow chart of insepction switch with camera function module BVS_ID...
Страница 341: ...956115_AA EN K22 Subject to modification...