BVS ID-M1280xF1-xx-xxx
22
english
Parameters
Description
Data
type
Active
Activates or deactivates the reading of a reference value.
Bool
String Length
Number of bytes representing the characters of the reference value.
Uint16
New Reference
Per Test Cycle
If
New Reference Per Cycle
is activated, the input buffer representing the
read in reference value is deleted after completion of an inspection program
run. The reference value can thus no longer be used in the following
inspection program run.
If
New Reference Per Cycle
is deactivated, the reference value is reused
until it is overwritten by a newly received data container.
Bool
Changing between configuration and monitor mode causes the reference value to be discarded if
New
Reference Per Cycle
is activated. If it is deactivated the reference value is retained in this case.
Changing the inspection program causes the reference value to always be discarded. For every new
inspection program a new data container has to be sent.
NOTE
Содержание BVS ID-M1280-F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Страница 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Страница 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Страница 106: ...BVS ID M1280xF1 xx xxx 104 deutsch Ablaufdiagramm eine Beispielinspektion mit Kamera Funktionsbaustein BVS_ID...
Страница 107: ...BVS ID M1280xF1 xx xxx deutsch 105 Ablaufdiagramm Inspektionsumschaltung mit Kamera Funktionsbaustein BVS_ID...
Страница 173: ...956115_AA DE K22 nderungen vorbehalten...
Страница 174: ......
Страница 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 176: ...www balluff com...
Страница 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Страница 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Страница 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...
Страница 273: ...BVS ID M1280xF1 xx xxx english 99 Flow chart of a sample inspection with camera function module BVS_ID...
Страница 274: ...BVS ID M1280xF1 xx xxx 100 english Flow chart of insepction switch with camera function module BVS_ID...
Страница 341: ...956115_AA EN K22 Subject to modification...