BVS ID-M1280xF1-xx-xxx
132
english
Bit position
Meaning
Description
3
Buffer Overflow Event
1 – buffer overflow
4
Timeout Event
1 – the set time for the minimum value/maximum value/
average calculation has elapsed
5
Reserved
-
6
Reserved
-
7
Reserved
-
System Commands
Command Value
Device Action
0xA7 (167)
Statistics Reset – Resets all output parameters to 0 and all user settings to the
default values.
0xA8 (168)
Statistics Start Min/Max/Avg – Starts the statistics of the minimum value/maximum
value/average calculation.
0xA9 (169)
Statistics Stop – Stops statistics operation completely.
0xAC (172)
Statistics Start Moving Average – Starts the statistics of the moving average
calculation.
Events
Event
Code
Event Type
Event – Description – Remedy
Device Status
0x8D07
(36103)
Warning
The calculation of the basic statistics was
stopped automatically to avoid a buffer overflow.
0 – Device is operating
properly.
0x8D0E
(36110)
Notification
The time has elapsed. This event reports the
timeout of the minimum value/maximum value/
average calculation.
It does not report a timeout for the calculation of
the moving average because the timer repeats
and it does not indicate the end of the calculation.
0 – Device is operating
properly.
Variant Dependence
The functionality is available in all variants.
Содержание BVS ID-M1280-F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Страница 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Страница 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Страница 106: ...BVS ID M1280xF1 xx xxx 104 deutsch Ablaufdiagramm eine Beispielinspektion mit Kamera Funktionsbaustein BVS_ID...
Страница 107: ...BVS ID M1280xF1 xx xxx deutsch 105 Ablaufdiagramm Inspektionsumschaltung mit Kamera Funktionsbaustein BVS_ID...
Страница 173: ...956115_AA DE K22 nderungen vorbehalten...
Страница 174: ......
Страница 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 176: ...www balluff com...
Страница 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Страница 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Страница 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...
Страница 273: ...BVS ID M1280xF1 xx xxx english 99 Flow chart of a sample inspection with camera function module BVS_ID...
Страница 274: ...BVS ID M1280xF1 xx xxx 100 english Flow chart of insepction switch with camera function module BVS_ID...
Страница 341: ...956115_AA EN K22 Subject to modification...