BTL5-A/C/E/G1_-M_ _ _ _-B/Z-NEX-S32/KA_ _
Micropulse Linear Transducer - Rod Style
6
english
Ignition Class "n"
4
Wiring (cont.)
Output signals
Pin
Cable
BTL5-A11
-C10
-C17
-E10
-E17
-G11
1
YE
yellow
not used
➀
0...20 mA
20...0 mA
4...20 mA
20...4 mA
not used
➀
2
GY
gray
0 V
3
PK
pink
10...0 V
not used
➀
10...–10 V
4
not used
5
GN
green
0...10 V
not used
➀
–10...10 V
➀
Unused leads can be tied to
GND on the control side, but they
must never be connected to the
shield.
➁
Reference GND for supply
voltage and EMC!
Supply voltage (external)
Pin
Cable
BTL5-A/C/E/G1_
6
BU
blue
GND
➁
7
BN
brown
+24 V
8
WH
white
do not connect
Table 4-1: Wiring
When routing the cable between
the transducer, controller and
power supply, avoid proximity to
high voltage lines to prevent noise
coupling. Especially critical is in-
ductive noise caused by AC har-
monics (e.g. from phase-control
devices), against which the cable
shield provides only limited protec-
tion.
Cable length max. 20 m; Ø 6 to
8 mm. Longer lengths may be used
if construction, shielding and routing
are such that external noise fields
will have no effect on signal integrity.
BKS connector, view
towards solder side of
female BKS-S32M-00
or BKS-S33M-00
Fig. 4-2: Pin assignments BKS,
connector type BTL
straignt BKS-S32M-00
No. 99-5672-19-08 (Binder part no.)
right-angle BKS-S33M-00
No. 99-5672-78-08 (Binder part no.)
Fig. 4-3: Connector (optional)
Cable entry (PG 9 fitting)