17
17
english
Function Description
Parametering the BIS C-60_3 processor
Reset_Option
class
:
64
Hex
instance
: 01
Hex
attribute
: 64
Hex
Factory setting:
Enable
(= 1)
In this setting the processor can be reset by the controller
using a High signal on the digital input.
Other settings:
Disable
(= 0)
Reset by the controller not possible.
Operating_Mode
class
:
64
Hex
instance
: 01
Hex
attribute
: 65
Hex
Factory setting:
no dynamic mode
(= 0)
This setting allows dynamic mode to be
enabled/disabled individually for each head.
Other settings:
dynamic head1
(= 1)
dynamic head2
(= 2)
dynamic head1 und 2
(= 3)
If the setting
dynamic mode
is not enabled for a head, a read
command from the controller is only carried out if there is a data carrier
in front of the read/write head. Otherwise the command is rejected
with error code 1.
If the setting
dynamic mode
is enabled for a head, the read/write
command is buffer stored and only carried out when there is a data
carrier in front of the read/write head (see 45).
Parameter 1
Reset-Option
Parameter 2
Dynamic mode
Head 1 / Head 2
C60_3-025_825645_1310_e.p65
18
english
18
Function Description
Parametering the BIS C-60_3 processor
DigIN_Mode
class:
64
Hex
instance: 01
Hex
attribute: 66
Hex
Factory setting:
Disable
(= 0)
In this setting the state of the digital input is not shown in the
bit header of the input buffer.
Other settings:
Enable
(= 1)
The state of the digital input is shown in the bit header of the
input buffer. If this function is selected, Parameter 4
HS_SL_Mode Disable (= 0) must remain set.
HS_SL_Mode
class:
64
Hex
instance: 01
Hex
attribute: 67
Hex
Factory setting:
2 heads
(= 0)
Select this setting if you want to operate the BIS C-60_3
Processor with 2 heads.
Other settings:
4 heads
(= 1)
Select this setting if you want to operate the BIS C-6003
Processor with a BIS C-655 read head adapter and 2 x 2
heads. If this function is selected, Parameter 3 DigIN_Mode
Disable (= 0) must remain set.
Setting/resetting the HD bit in the bit header allows you to
switch between Head 1.1 and Head 1.2 as well as Head 2.1
and Head 2.2 (in the BIS using the relay).
Parameter 3
State of the digital
input
Parameter 4
Read/write head
selection