The figure shows the object model of the BIS C-60_3 Processor. The „BIS Config Object“
reflects the configuration properties of the device, and the „BIS R/W Object“ the two read/
write heads.
BUS interface DeviceNet
Object model
(continued)
Application Objects
DeviceNet
BIS R/W Object Class
BIS R/W Object
BIS Config
Objekt
Message
Router
Identity
Object
Assembly
Object
DeviceNet
Object
Explicit
Message
Polled
IO
Connection Class
C60_3-025_825645_1310_e.p65
14
english
14
BUS interface DeviceNet
Setting the MAC-ID
The MAC-ID of the BIS C-60_3 Processor can be set using the slide switch S1.1 - 1.6. The
slide switch S1.1 - 1.6 is binary coded. The station address is set as shown in the table:
Head
X4
RS 232
X1
X2
X3
S1
1
2
3
4
5
6
7
8
OFF ON
S2
1
2
ON OFF
Head 1
Head 2
Slide switch S1
(cover opened)
➪
S2
1
2
ON OFF
The baud rate of the BIS C-60_3 Processor can be
set using slide switch S2. The following settings are
possible:
Setting the baud rate
MAC-ID
Slide switch S1
6
5
4
3
2
1
2
5
2
4
2
3
2
2
2
1
2
0
0
OFF
OFF
OFF
OFF
OFF
OFF
1
OFF
OFF
OFF
OFF
OFF
ON
2
OFF
OFF
OFF
OFF
ON
OFF
3
OFF
OFF
OFF
OFF
ON
ON
4
OFF
OFF
OFF
ON
OFF
OFF
...
42
ON
OFF
ON
OFF
ON
OFF
...
63
ON
ON
ON
ON
ON
ON
S1
1
2
3
4
5
6
7
8
OFF ON
➪
Baud rate
Slide switch S2
2
1
2
1
2
0
125 kBaud
OFF
OFF
250 kBaud
OFF
ON
500 kBaud
ON
OFF
invalid
ON
ON
CAUTION:
Position S1.7 and S1.8 must always be
OFF