1
Intended use
The inductive positioning system BIP with IO-Link
interface, together with a machine controller (PLC) and an
IO-Link master, comprises a positioning/displacement
measurement system. It is intended to be installed into a
machine or system and used in the industrial sector.
Opening the inductive positioning system or non-approved
use are not permitted and will result in the loss of warranty
and liability claims against the manufacturer.
Downloading further instructions
A complete user's guide can be downloaded from the
Internet at
www.balluff.com
or requested via e-mail from
.
Dimensions and function
The BIP inductive positioning system provides an IO-Link
output signal which changes proportional to the position of
a metallic target.
L
22.1
32.4
L–2
55.3
23
21
17
M8x1
BIP
R3
A
2
Active surface
Target
1)
LED
Mounting clamps and cylinder head screws
ISO 4762 M4x12,
max. tightening torque 3 Nm
Type
L
A
2)
BIP LD2-
T048
-03-S75
64.0
28
BIP LD2-
T070
-03-S75
92.5
60
BIP LD2-
T103
-03-S75
121.0
89
BIP LD2-
T133
-03-S75
149.5
118
1) Not included in scope of delivery
2) Recommended fastener spacing
General safety notes
Installation
and
startup
may only be performed by
trained specialists.
The
operator
is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the inductive positioning system will not result in
hazards to persons or equipment.
If defects and unresolvable faults occur in the inductive
positioning system, take it out of service and secure
against unauthorized use.
Cable routing
Defined ground!
The BIP and the control cabinet must be at the
same ground potential.
Magnetic fields
The BIP operates according to the eddy current principle.
It is important to maintain adequate distance between the
BIP and strong, external magnetic fields.
Cable routing
Do not route the cable between the BIP, controller, and
power supply near high voltage cables (inductive stray
noise is possible).
Inductive stray noise from AC harmonics (e.g. from phase
angle controls) are especially critical and the cable shield
offers very little protection against this.
Cable length
Max. cable length 20 m. Longer cables may be used
if their construction, shielding and routing prevent noise
interference.
Electrical connection
4
2
1
3
Pin assignment of S75 connector
(view from above on connector of BIP)
Pin
Wire color
Signal
1
Brown
L+ (18…30 V)
2
–
Not used
3)
3
Blue
L− (GND)
4
Black
C/Q (communication line)
3) Unassigned leads can be connected to the GND on the controller side
but not to the shield.