Page 9
EL1500 - 40916_01_C
Program Filter Cycles by Duration
n
Y
n
=
Start and stop times; for time capable panels.
Y
=
Duration; for non-time capable panels
=
1 DIP Switch
Pump 1 in Filter (w/Circ Pump)
n
Y (This feature is used in Circ Mode only.)
Allows Pump 1 Low to operate in Filter Cycles to add extra filtration.
n
=
Normal;
Y
=
Pump 1 with Circ
24-Hour
Time*
n
Y
n
=
12-hour (am/pm);
Y
=
24-hour (military\European);
=
1 DIP Switch
*Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Celsius**
n
Y
n
=
Fahrenheit;
Y
=
Celsius;
=
1 DIP Switch
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up
Timeouts
1
F
2 3 4 5 6
1-6 =
10, 20, 30, 40, 50, 60 minutes;
F =
15 minutes
Pump 1 Low Timeout
d
1
2
3 4
d =
Use “Timeouts” value above;
1-4 =
number of hours;
=
3 DIP Switch
Light
Timeout
d 1 2 3
4
d =
Use “Timeouts” value above;
1- 4 =
number of hours
Scrunch
Panel
n
Y
n
=
Normal panel layout;
Y
=
Alternate panel layout (ML900 scrunching enabled - ML550/700
Jets 3 replaces Blower;
=
1 DIP Switch
Circ Type (behavior)
n
A 3 P
n
=
Non circ or circ pump not plumbed with heater;
A
=
24-hour;
3
=
24-hour with 3ºF shutoff outside filter;
P =
Acts like Pump 1 Low (filter cycles, polls, etc.);
=
2 DIP Switch
Software Configuration Settings
OEM Setting (Green circle)
n =