Page 13
EL1500 - 40916_01_C
Lowest Set Temperature*
8
7
8 =
80˚F/26.0˚C;
7 =
70˚F/21.0˚C
*Setting LS at 7 and Fr at 5 will cause a CFE error.
Default
Set
Temperature**
5 6 7 8 9
0
1 2 3 4 E F n
5 =
95˚F/35.0˚C;
6 =
96˚F/35.5˚C;
7 =
97˚F/36.0˚C;
8 =
98˚F/36.5˚C;
9 =
99˚F/37.0˚C;
0 =
100˚F/38.0˚C;
1 =
101˚F/38.5˚C;
2 =
102˚F/39.0˚C;
3 =
103˚F/39.5˚C;
4 =
104˚F/40.0˚C;
E =
80˚F/26.5˚C;
F =
85˚F/29.5˚C
n =
90˚F/32.0˚C
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Uppermost
Set
Temperature
5 6 7 8 9 0 1 2 3
4
E F n
5 =
95˚F/35.0˚C;
6 =
96˚F/35.5˚C;
7 =
97˚F/36.0˚C;
8 =
98˚F/36.5˚C;
9 =
99˚F/37.0˚C;
0 =
100˚F/38.0˚C;
1 =
101˚F/38.5˚C;
2 =
102˚F/39.0˚C;
3 =
103˚F/39.5˚C;
4 =
104˚F/40.0˚C;
E =
80˚F/26.5˚C;
F =
85˚F/29.5˚C
n =
90˚F/32.0˚C
Freeze Temperature Threshold
3
4
9 5
3 =
39˚F/3.9˚C;
4 =
44˚F/6.7˚C;
9 =
49˚F/9.4˚C;
5 =
54˚F/12.2˚C;
Set Temperature Lock
t
S
t
=
Temp Lock Only;
S
=
Temp + Settings Lock
Software Configuration Settings Continued
T
EMPERA
TURE
S
ETTINGS