Table 4: Reciprocating Valve Mounting Hole and Turnbuckle Length
Masoneilan
Actuator Size
Stroke
Mounting
Hole
Lever
Hole
Turnbuckle
Length
6 and 10
0.5 - 0.8"
(12.7 - 20.32 mm)
A
A
1.25"
(31.75 mm)
10
0.5 - 0.8"
(12.7 - 20.32 mm)
A
A
1.25"
(31.75 mm)
10
>0.8 – 1.5"
(20.32 - 41.5 mm)
B
B
1.25"
(31.75 mm)
16
0.5 - 0.8"
(12.7 - 20.32 mm)
B
A
2.90"
(73.66 mm)
16
>0.8 – 1.5"
(20.32 - 41.5 mm)
C
B
2.90"
(73.66 mm)
16
>1.5 – 2.5"
(41.5 - 63.5 mm)
D
C
2.90"
(73.66 mm)
23
0.5 - 0.8"
(12.7 - 20.32 mm)
B
A
5.25"
(133.35 mm)
23
>0.8 – 1.5"
(20.32 - 41.5 mm)
C
B
5.25"
(133.35 mm)
23
>1.5 – 2.5"
(41.5 - 63.5 mm)
D
C
5.25"
(133.35 mm)
© 2018 Baker Hughes, a GE company, LLC. All rights reserved
.
Masoneilan SVI II AP Digital Positioner Quick Start Guide
=
|
33
Dismantling the SVI II AP from Reciprocating Valves
WARNING
Before carrying out any work on the device, power off the
instrument or ensure that the local conditions for potentially
explosive atmosphere permit the safe opening of the cover.
To remove the SVI II AP Controller from a reciprocating valve perform Steps 1 - 12 on page
30 in
the reverse order.
Содержание Masoneilan SVI II AP
Страница 6: ...This page intentionally left blank...
Страница 10: ...This page intentionally left blank...
Страница 68: ...This page intentionally left blank...
Страница 90: ...2018 Baker Hughes a GE company LLC All rights reserved 90 BHGE Spare Parts...
Страница 92: ...2018 Baker Hughes a GE company LLC All rights reserved 92 BHGE...
Страница 94: ...This page intentionally left blank...
Страница 102: ...This page intentionally left blank...
Страница 105: ...This page intentionally left blank...
Страница 106: ...This page intentionally left blank...
Страница 107: ...This page intentionally left blank...