Operation
PCA
TABLE 4-1. COMMA-DELIMITED FIELDS
Field
Data Name or Value
Label in Column
Headings
1
Instrument serial number
SN
2
ID line 1 (up to 16 characters)
ID1
3
ID line 2 (up to 16 characters)
ID2
4
ID line 3 (up to 16 characters)
ID3
5
Time of test (hh:mm:ss)
TIME
6
Date of test (dd.mm.yyyy)
DATE
7
1
Name of fuel (up to 16 characters)
FUEL
8
1
Flue gas temperature
TS
9
1
Air temperature
TA
10
1
Temperature unit of measure (°F or °C) C/F
11
1
O
2
concentration in % O2
12
1
CO
2
concentration in % C2
13
1,2
CO concentration in ppm CO
14
1,2
CO referenced to nn% O
2
in ppm
CF
15
1,3
NO concentration in ppm
NX
16
1,3
NO referenced to nn% O
2
in ppm
NF
17
1,2
O
2
Reference used in fields 14 and 16 O2R
18
1
Combustion efficiency in %
EF
19
1
Excess air in %
EA
20
Draft measurement
DR
21
Draft unit of measure
MB/PA/WC
1
Empty data field for draft tests
2
Empty data field for PCA Models 10, 15, 40 and 45
3
Empty data field for PCA Models 10, 15, 20, 25, 40, 45, 50, and 55
TABLE 4-2. TYPICAL SPREADSHEET FOR A PCA 65
SN
ID1
ID2
ID3
TIME
DATE
FUEL
TS
TA C/F O2
AX1020 ID LINE 1
ID LINE 2
ID LINE 3 9:03:27 PM 2/24/1999 NATGAS 374 68 F
4
AX1020 ID LINE 1
ID LINE 2
ID LINE 3 9:10:35 PM 2/24/1999
C2 CO CF
NX NF O2R EF EA DR
MB/PA/WC
9.5
12
13
10
11
3
82.2
21
-0.25
WC
-0.25 WC
Line 1: Column Headings
Line 2: Typical Combustion Readings
Line 3: Typical Draft Readings
4-16
Instruction 0024-9219
Содержание Portable Combustion Analyzer
Страница 12: ...Technical Characteristics NOTES PCA 2 4 Instruction 0024 9219...
Страница 60: ...Calibration PCA NOTES 5 12 Instruction 0024 9219...
Страница 81: ...PCA Parts Service Figure 8 1 Replacement Parts 1 of 3 Instruction 0024 9219 8 3...
Страница 83: ...PCA Parts Service Figure 8 1 Replacement Parts 3 of 3 Instruction 0024 9219 8 5...
Страница 90: ...Appendix B PCA NOTES B 2 Instruction 0024 9219...