Troubleshooting
TABLE 7-1. TROUBLESHOOTING GUIDE (Cont.)
PCA
Fault
Probable Cause & Remedy
Backlight will not turn on.
Batteries do not last 10 hours.
Erratic Combustion Test Screen
values.
Analyzer will not calibrate prop-
erly.
Backlight LED burned out. Return
to Bacharach for repair.
Cold temperature is reducing bat-
tery capacity. To obtain longer oper-
ating time, keep analyzer warm.
a. Faulty sensor(s):
- Check that the sensors are prop-
erly installed per Sections 6.6
through 6.8.
- Check sensor calibration per
Section 5.0.
- Replace sensor(s) and recal-
ibrate per Sections 5.0 and 6.0.
b. Probe assembly leaking. Check
tightness of all hose connections
and integrity of tubing.
c. Pump defective. Replace pump &
motor assembly.
d. Analyzer defective. Return to
Bacharach for repair.
a. Wrong calibration gas or insuffi-
cient flow being applied to sensor.
Ensure your calibration setup is
correct.
b. Faulty sensor. Replace sensor and
recalibrate per Sections 5.0 and
6.0.
c. Analyzer defective. Return to
Bacharach for repair.
7-6
Instruction 0024-9219
Содержание Portable Combustion Analyzer
Страница 12: ...Technical Characteristics NOTES PCA 2 4 Instruction 0024 9219...
Страница 60: ...Calibration PCA NOTES 5 12 Instruction 0024 9219...
Страница 81: ...PCA Parts Service Figure 8 1 Replacement Parts 1 of 3 Instruction 0024 9219 8 3...
Страница 83: ...PCA Parts Service Figure 8 1 Replacement Parts 3 of 3 Instruction 0024 9219 8 5...
Страница 90: ...Appendix B PCA NOTES B 2 Instruction 0024 9219...