Operation
4.2 Sampling Hole Location
PCA
The analyzer requires that a ½" diameter sampling hole be made in the
furnace stack to accommodate the probe stop on the Probe and Hose
Assembly.
Locate the sampling hole downstream from the last heat exchanger,
and upstream from any source of dilution, such as a draft diverter
(Figure 4-1).
Important! As the distance between the last heat exchanger
and sampling point increases, stack loss will falsely decrease
due to heat loss by convection from the flue or stack.
For residential and light-commercial combustion-equipment applications,
the following recommendations are applicable:
• Oil Gun Burners
– Locate sampling hole at least 12 in. (30 cm) down-
stream from the furnace breaching, and at least 6 in. (15 cm) upstream
from the furnace side of the draft regulator.
• Gas Burners
– Locate sampling hole
at least 6 in. (15 cm) upstream from
the furnace side of the draft diverter
on gas-converted units. For gas-
designed equipment, the probe may
be inserted down into the flue
through the draft diverter or hood.
FLUE GAS FLOW
(Downstream)
DRAFT
DIVERTER/
REGULATOR
SAMPLE
POINT
(Upstream)
FURNACE
BREECHING
Figure 4-1. Sampling Hole Location
4-2
Instruction 0024-9219
Содержание Portable Combustion Analyzer
Страница 12: ...Technical Characteristics NOTES PCA 2 4 Instruction 0024 9219...
Страница 60: ...Calibration PCA NOTES 5 12 Instruction 0024 9219...
Страница 81: ...PCA Parts Service Figure 8 1 Replacement Parts 1 of 3 Instruction 0024 9219 8 3...
Страница 83: ...PCA Parts Service Figure 8 1 Replacement Parts 3 of 3 Instruction 0024 9219 8 5...
Страница 90: ...Appendix B PCA NOTES B 2 Instruction 0024 9219...