Instruction 24-9395
20
Fyrite Pro
Atmospheric Burner or
Gravity Vented Forced Air
hot Water Tank
4.2.3 Sampling Point
Forced Air Furnace
– When testng atmospherc burner or gravty
vented, forced ar heatng equpment wth a clamshell or sectonal heat
exchanger desgn, test each of the exhaust ports at the top of the heat ex-
changer. The probe should be nserted back nto each of the exhaust ports
to obtan a flue gas sample, before any dluton ar s mxed n.
Hot Water Tank
– Domestc hot water tanks wth the ‘bell’ shaped draft
dverter on top can be accurately tested by nsertng the probe tp drectly
nto the top of the fre tube below the dverter.
80% Efficiency Fan Assist or Power Vented
– Combuston testng of
fan assst or power vented, furnaces/bolers should be done through a hole
drlled n the vent mmedately above the nducer fan.
90% Efficiency Condensing
– Condensng furnaces/bolers can be tested
through a hole drlled n the plastc vent ppe (when allowed by the manufac-
turer or local authorty of jursdcton) or taken from the exhaust termnaton.
Atmospheric or Gravity Vented Boiler
– Bolers, whch have a ‘bell’
shaped draft dverter drectly on top, should be tested drectly below the
dverter through a hole drlled n the vent connector.