C200 series bench scales service manual
- 16 -
C200 Series Bench Shortcut Page
Scale Configuration and Calibration
Enabling lbs Unit
From normal weighing mode, press and hold
MODE
until display shows Fset. Display will then show
“F0 SEL”
Use
ZERO/TARE
to step forward through the parameters until “F15 Ut” is displayed.
To toggle between parameter name and current setting, press
MODE
To
change,
press
ZERO/TARE
with current setting displayed.
To back up, press “ADD”
Toggling Units from the Weighing Mode
Press
RE
. Display will toggle between lbs and kg.
Scale Configuration
Hold
MODE
while powering on, until self-test “-1.99999” appears
Indicator will power up in weigh mode, an “
M
” will be displayed in the lower-left corner of the display
Hold
MODE
” until “FUnC” is displayed. Display will then show “F0 iSn”
Use
ZERO/TARE
to step forward through parameters until “F2 d m” is displayed.
Press
MODE
until dESC is displayed, this is the decimal point parameter
To toggle between parameter name and current setting, press
MODE
To change, press
ZERO/TARE
with current setting displayed
To back up, press
ADD
Press
ZERO/TARE
to advance to next parameter, “inC”. This is the display increment setting.
To toggle between parameter name and current setting, press
MODE
To change, press
ZERO/TARE
with current setting displayed
To back up, press
ADD
Press
ZERO/TARE
to advance to the next parameter, “CAP”. This is the capacity setting.
To toggle between parameter name and current setting, press
MODE
To change: With current capacity setting displayed, press “C/AC”, then type in correct capacity on
numeric keypad.
To back up, press
ADD
Press
ZERO/TARE
to advance to the next parameter, “CAL”. This is scale calibration.
Press
MODE
Display will show “nonLin”.
With no weight on the platform, press
MODE
display will show “UnLoAd”
After a pause of 30 seconds to 1 minute, display will show “LoAd”. Apply calibration weight to platform.
Nothing needs to be pressed on the keypad, the indicator will sense the applied weight automatically.
After a pause of 30 seconds to 1 minute, display will show “PASS” and indicator will re-boot.