C200 series bench scales service manual
- 8 -
5. 5 Limit set and Comparing
5.5.1 Limit Set
Before use this function, please be sure limit function must be set enable ( see detail
in parameter (F0. sel) setting table), you can set either one point or two points limit.
Press LMT key.
Li-LO
appear at Weighing display, and low limit value shows
that currently set at UNIT.W display, enter low limit value with numerical keys, press
LMT key. Low limit set, and a beep will sound. Then
Li-HI
appears at Weighing
display, and high limit value shows that currently set at UNIT.W display, then
advance to the high limit, enter high limit value with numerical keys, press LMT key.
High limit set, and a beep will sound. High limit set, and go back to working area.
5.5.2 Look up limit values
Press LMT key.
Li-LO
appears at Weighing display, and low limit value shows what
is currently set at UNIT. W display. Press LMT key.
Li-HI
appears on the Weighing
display, and high limit value shows what is currently set at UNIT.W display. Press
LMT key. Go back to working area.
In case that only one point (F3.Pn. 1) is selected to set, low limit value shows after
press LMT key at once go back to working area.
5.5.3 Comparing ( how limit function work )
Suppose two limits have been set;
When the quantity is under the low value, it is ranked as “ LO “
When the quantity is between the low value and the high, it is ranked as “ OK “
When the quantity is over the high value, it is ranked as “ HI “
Notes
# Such settings as lower limit value >= Higher limit value will be error.
# Comparative judgment condition;
At one point(F3.Pn. 1) :
L O : v a l u e < lower limit.
OK: lower limit =< value.
At two point(F3.Pn. 2) :
LO: value < lower limit
OK: lower limit =< value =< higher limit
HI : higher limit< value
# We get beep sound in response to comparing result.
The condition is selectable by function set.