60
Arguments
Type:
Character
Options:
SINusoid, TRIangle, SQUare
Command Type:
Setting or Query
Setting
Syntax:
[:SOURce:]FM:SHAPe<ws><SIN|TRI|SQU>
Examples:
[:SOURce:]FM:SHPE SIN
FM:SHAPE TRI
Query
Syntax:
[:SOURce:]FM:SHAPe?
Response:
SIN|TRI|SQU
FM FREQuency
This command sets the FM modulating waveform frequency
Arguments
Type:
Numeric.
Units:
MHz, KHz, Hz (default)
Range:
Fmax = 20 KHz
Fmin = 0.01 Hz
Rounding:
The value is rounded to 4 digits.
Command Type:
Setting or Query
Setting
Syntax:
[:SOURce:]FM:FREQuency<ws><frequency>[units]
[:SOURce:]FM:FREQuency<ws>MINimum|MAXimum
Examples:
FM:FREQ 5KHZ
FM:FREQ 5E3
FM:FREQ MAXIMUM
FM:FREQ MIN
Query
Syntax:
[:SOURce:]FM:FREQuency?[<ws>MAXimum|MINimum]
Examples:
FM:FREQ?
FM:FREQ? MAX
Response:
NR3
FM SOURce
This command selects the FM modulation source as either internal (then the above settings are
effective) or external (and then the external waveform determines deviation, shape and frequency of
modulation).
Arguments
Type:
Character
Options:
INTernal, EXTernal
Command Type:
Setting or Query
Setting