Setting up the unit
To activate the unit, connect the appropriate included power cable to the unit and to a suitable 230V, 50Hz
power outlet.
During start-up, the device needs to calibrate. This may take up to one minute. During start-up the display
reads 'AYRA' and the fixture cannot be used. Do not try to enter the menu during start-up. When the start-up
is complete, the last used mode will be shown and the settings and values can be changed. For a new
product, this is usually the DMX mode with the value set to 001. If no DMX signal is present, the device will
turn to an auto or music mode.
Through the menu and the buttons below the display, you are able to adjust settings and read data from the
fixture.
Use the display and the menu buttons on the bottom to set preferences, change settings and scroll through
the menu. “Enter” is used to save a certain setting or preset; press “Menu” for at least 2 seconds to return to
the main menu.
The table below shows an explanation for every feature and value.
display
Mode
Function
ADDR
DMX address setting
Address 001 … 512
CHND
Channel mode
1CH/3CH/4CH/6CH/16CH/18CH/48CH/49CH/50
CH/51CH
SLND
Slave mode
Slave (normal slave mode)
Slave 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15,
16 (matrix mode stand alone light show)
SHND
Show mode
TLSH: One/Two light show
FLSH: Four light show
SLSH: Sixteen light show
SOUN
Sound mode
Sound operated mode on/off
SENE
Sound sensitivity
Sound sensitivity 0-100
BALA
White balance correction
Red: 000-255
Green: 000-255
Blue: 000-255
BLND
Blackout mode
LED display on/off when not in use
DISP
Display inversion
Flips display for easier reading
TEST
Test mode
Tests all LEDs and colours
TEMP
Temperature
Temperature display (Celsius)
HOUR
Working hours
Amount of hours device has been used, 0-9999
ADDR:
DMX address setting, used to determine the DMX starting channel. From this channel on, the fixture
will respond to values corresponding with the number of channels that the fixture is occupying. (For example,
when you set the starting address to value 003, the fixture will respond to channels 3, 4, 5 etc.)
CHND:
The channel mode of the fixture makes it possible to use the correct channel mode setting for every
application. For simple and basic setups, users may prefer to use the 1 CH mode. For advanced setups,
users may prefer to choose the 51CH mode to be able to control the colour of every pixel and function.
SLND:
Select the right master or slave operation for the fixture. The usual mode is the master mode. If you
select Slave mode 1, the device will mimic the actions of the first. If you set the slave mode to 2 or further,
complete matrix show designs can take place (when also setting the correct SHND mode).
To use the master-slave mode, connect two fixtures together with standard 3P XLR male – 3P XLR female
cable (not included). Connect the DMX output of the master to the DMX input of the slave function.
Regardless of the mode selected on the master fixture, the slave will mimic the actions.
NOTE:
Please note that it is not possible to switch to any working mode if the Slave mode is active on your
fixture!
All information and illustrations shown in this user manual are subject to change without further notice.
User manual version: 1.0
Creation date + author initials: 13-05-2015 RV Revision date + author initials: